TROUBLESHOOTING & REPAIR |
THERMAL PROTECTION AC TRIGGER CIRCUIT
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and pre- cautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to per- form the test / repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
TEST DESCRIPTION
This procedure will check the two thermostats and associated circuity through the
Auxiliary Transformer, Power Board and Control Board.
MATERIALS NEEDED
Volt/Ohm Meter
Misc. Hand Tools
Wiring Diagram (Section G)