TROUBLESHOOTING & REPAIR |
OVERCURRENT PROTECTION CURRENT TRIGGER TEST (cont.)
FIGURE F.14 - CONTROL BOARD TEST POINTS
|
|
|
|
|
| 2J3 (White) |
J5 | G2527 | CONTROL | J1 | J2 | J4 | J3 |
| ||||||
6. Turn main power OFF. |
|
|
|
|
| 1J3 (Black) |
|
|
|
|
|
| |
7. Perform Input Filter Capacitor Discharge | NOTE: On earlier codes the terminals on the shunt | |||||
Procedure detailed in this section. |
| leads were crimped but not soldered. Corrosion may | ||||
|
|
| cause inaccurate current readings. Cleaning and sol- | |||
Test resistance of the Black and White leads from | dering the terminals to the leads may eliminate that | |||||
1J3 and 2J3 to the shunt. See Figure F.14. | problem. |
|
|
| ||
a. If zero ohms resistance (continuity) is shown, | If tests for steps 5, 7, are OK and the machine contin- | |||||
test is OK. |
|
| ues to experience the problem, the Control Board | |||
|
|
| should be replaced. |
|
|
b.If resistance of any value is shown, check wire and connections.
FIGURE F.15 - OVERCURRENT PROTECTION CURRENT TRIGGER CIRCUIT.
302275D
6J1 1J1
CONTROL
BOARD
1J3 | 2J3 |
BLACK | WHITE |
L3 |
|
| 400 AMP | |
CHOKE | SHUNT | TERMINAL |