TROUBLESHOOTING & REPAIR | ||
|
|
|
POWER BOARD TEST (cont.)
FIGURE F.23 - POWER BOARD TEST POINTS
309 | 310 |
| 212A |
| 301 302 |
| L8033 | POWER BOARD |
|
| |
|
|
|
|
| |
J7 | 313 | J14 |
| J6 | 275D |
| 311 | 211A |
| ||
501 |
| 305 | |||
|
|
|
|
| |
504 |
|
|
|
|
|
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
6.Test for 18 VAC input from Auxiliary Transformer between leads 504 and 501
If 18 VAC is not correct, check the 3 amp fuse, the Auxiliary Transformer and associated wires.
7.Test for 15 VDC output between leads 275D
If 15 VDC output is not present, replace Power Board.
NOTE: If relays energized in Step 4a, skip to Step 10.
8.Test for 24 VAC from lead 211A t to lead 212A (J6- pin 4 & pin 9).
If 24VAC is not present, test the Auxiliary trans former and associated wires. The Control Board or thermostats may also be defective. (See Fig. F.24).
9.Test for 24VDCfrom lead 309(+) to lead
If 24VDC is not present but 24VAC (step 8) is cor rect, the Power Board is defective.
10.Test for 24VDC from lead 309(+) to lead
If 24 VDC is not present, check the voltage from lead 311(+) to lead
If the voltage is greater than 1VDC, perform the Protection Board test.
If the voltage is approximately 1vdc and the 24vdc is not present between leads 309 & 310, the Power Board is defective