Lincoln Electric IM10044 manual Installation

Page 11

 

A-1

 

 

 

 

INSTALLATION

 

 

A-1

 

TECHNICAL SPECIFICATIONS - VANTAGE® 575 CUMMINS (K2170-2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT - DIESEL ENGINE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Make/Model

 

Description

 

Speed (RPM)

 

Displacement

Starting

Capacities

 

 

 

 

 

 

 

 

 

 

 

cu. in. (ltrs.)

System

 

 

 

 

 

4 cylinder

 

High Idle 1590

 

199(3.3)

 

12VDC Battery &

Fuel: 25 gal.

 

 

Cummins

 

48 HP (36kw)

 

 

 

 

 

 

starter

(94.6 L)

 

 

 

 

 

 

 

 

 

 

 

B3.3

 

1500 RPM

 

Full Load 1500

 

Bore x Stroke inch (mm)

 

 

Oil: 2 gal. (7.5L)

 

 

 

 

Diesel Engine

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Idle 1300

 

3.74 X 4.53

 

 

Radiator Coolant:

 

 

 

 

 

 

 

 

 

 

 

(95 x 115mm)

 

 

2.6gal. (9.8L)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT @ 104°F(40°C) - WELDER

 

 

 

Duty Cycle

 

 

Welding Output

 

 

Volts at Rated Amps

 

 

100%

 

 

 

450 Amps (DC multi-purpose)

 

 

38 Volts

 

 

 

60%

 

 

 

500 Amps (DC multi-purpose)

 

 

40 volts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT @ 104°F(40°C) - WELDER AND GENERATOR

 

 

 

 

 

 

 

 

 

Welding Range

 

 

 

 

 

 

 

 

 

 

 

30 - 575 Amps CC/CV

 

 

 

 

 

 

 

 

 

 

 

20 - 250 Amps TIG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open Circuit Voltage

 

 

 

 

 

 

 

 

 

 

 

60 Max OCV @ 1590 RPM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary Power (1) (50 Hz)

 

 

 

 

 

 

 

Outlets x Phase

Voltage

Power

Amps

 

 

 

 

 

 

1 x 3ph

415 Volts

20 Kva

32 Amps

 

 

 

 

 

 

2 x 1ph

240 Volts

7.2 Kva

15 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

 

Height (2)

 

 

Width

 

Depth

 

Weight

 

 

42.0 in

 

 

32.7 in.

 

63.1 in.

 

1625 lbs.

 

 

(1066.8 mm)

 

 

(830.1mm)

 

(1603mm)

 

(737kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Approx)

 

1.Output rating in watts is equivalent to volt-amperes at unity power factor.

Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.

2.Top of Enclosure, add 7.0” (177.8mm) for exhaust pipe.

VANTAGE® 575 CUMMINS

Image 11
Contents Vantage Cummins California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéElectromagnetic Compatibility EMC Safety Thank You Table of Contents Table of Contents Installation Stacking Safety PrecautionsLocation and Ventilation StoringTowing High Temperature OperationLifting High Altitude OperationFuel USE Diesel Fuel only PRE-OPERATION Engine and COM- Pressor ServiceBattery Connection OILWelding Terminals AIR Cleaner Inlet HoodMuffler Outlet Pipe Spark ArrestorStandby Power Connections Remote ControlAuxiliary Power Receptacles Control Cable Model Connection of Lincoln ELEC- Tric Wire FeedersConnection of LN-15 to the Vantage 575 CUM Across The-Arc ModelShut off welder before making any electrical con- nections Connection of the LN-25 to the VAN- Tage 575 CumminsRecommended Applications Safety PrecautionsOperation General DescriptionControls and Settings Engine Protection Battery Charging LightIdler Switch OIL Pressure GaugePIN Connector Weld Mode Selector SwitchWelding Terminals Switch Wire Feeder Voltmeter SwitchBattery Jump Start Terminal What are VRD and Rocv DEVICES? Welding Power SourcesSafety VRD Operation IndicatorTable B.1 Cummins B3.3 Engine Fuel Consumption Starting TechniqueBREAK-IN Period Typical Fuel ConsumptionWelder Operation Stick Welding ModeCC-STICK Mode Touch Start TIG ModeTable B.3 Typical Current Ranges Wire WELDING-CVARC Gouging Carbon Diameter Current Range DC, elec Trode positiveParalleling Auxiliary Power OperationSimultaneous Welding and Auxiliary Power Loads TIG Options AccessoriesOptional Field Installed Accessories Weekly MaintenanceRoutine and Periodic Maintenance Daily Engine MaintenanceService Instructions Fuel Filters Battery HandlingPreventing Battery Discharge Preventing Battery BucklingWelder / Generator MAINTE- Nance HOW to USE Troubleshooting Guide TroubleshootingContact your local Lincoln Authorized Field Service FacilityTroubleshooting PCB Wiring Diagram Diagrams To Work Electrode Cable To Wire Feed Unit Engine Welders / K867 / K775 / LN-7 Connection DiagramDiagrams Diagrams Engine Welders / K867 / LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams 736 634 24 .97 Dimension PrintPrecaucion Warnung