Lincoln Electric IM10044 manual Connection of the LN-25 to the VAN- Tage 575 Cummins

Page 18

A-8

INSTALLATION

A-8

 

 

 

CONNECTION OF THE LN-25 TO THE VAN- TAGE® 575 CUMMINS.

WARNING

Shut off welder before making any electrical con- nections.

--------------------------------------------------------------------------

The LN-25 with or without an internal contactor may be used with the VANTAGE® 575 CUMMINS. See the appropriate connection diagram in Section F.

NOTE: The LN-25 (K431) Remote Control Module and (K432) Remote Cable are not recommended for use with the VANTAGE® 575 CUMMINS.

1.Shut the welder off.

2.For electrode Positive, connect the electrode cable from the LN-25 to the "+" terminal of the welder and work cable to the "-" terminal of the welder. For electrode Negative, connect the electrode cable from the LN-25 to the "-" terminal of the welder and work cable to the "+" terminal of the welder.

3.Attach the single lead from the front of the LN-25 to work using the spring clip at the end of the lead. This is a control lead to supply current to the wire feeder motor; it does not carry welding current.

4.Set the MODE switch to the "CV-WIRE " position.

5.Set the "WELD TERMINALS" switch to "WELD

TERMINALS ON"

6.Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

7.Set the "IDLE" switch to the "AUTO" position. When not welding, the VANTAGE® 575 CUMMINS engine will be at the low idle speed. If you are using an LN-25 with an internal contactor, the electrode is not energized until the gun trigger is closed.

8.When the gun trigger is closed, the current sensing circuit will cause the VANTAGE® 575 CUMMINS engine to go to the high idle speed, the wire will begin to feed and the welding process started. When welding is stopped, the engine will revert to low idle speed after approximately 12 seconds unless welding is resumed.

CAUTION

If you are using an LN-25 without an internal con- tactor, the electrode will be energized when the VANTAGE® 575 CUMMINS is started.

--------------------------------------------------------------------------

CONNECTION OF AN NA-3 AUTOMATIC WELDING SYSTEM TO THE VANTAGE® 575 CUMMINS

For connection diagrams and instructions for connect- ing an NA-3 Welding System to the VANTAGE® 575 CUMMINS, refer to the NA-3 Welding System instruc- tion manual. The connection diagram for the LN-8 can be used for connecting the NA-3.

• Set the Wire Feeder Voltage Switch to 115V.

CONNECTION OF MAGNUM SC SPOOL GUN TO THE VANTAGE® 575 CUMMINS (SEE SECTION F)

Spool Gun (K487-25) and Cobramatic to VAN- TAGE® 575 CUMMINS.

Shut the welder off.

Connect per instructions on the appropriate connec- tion diagram in Section F.

VANTAGE® 575 CUMMINS

Image 18
Contents Vantage Cummins Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcElectromagnetic Compatibility EMC Safety Thank You Table of Contents Table of Contents Installation Storing Safety PrecautionsLocation and Ventilation StackingHigh Altitude Operation High Temperature OperationLifting TowingOIL PRE-OPERATION Engine and COM- Pressor ServiceBattery Connection Fuel USE Diesel Fuel onlySpark Arrestor AIR Cleaner Inlet HoodMuffler Outlet Pipe Welding TerminalsRemote Control Auxiliary Power ReceptaclesStandby Power Connections Across The-Arc Model Connection of Lincoln ELEC- Tric Wire FeedersConnection of LN-15 to the Vantage 575 CUM Control Cable ModelConnection of the LN-25 to the VAN- Tage 575 Cummins Shut off welder before making any electrical con- nectionsGeneral Description Safety PrecautionsOperation Recommended ApplicationsControls and Settings OIL Pressure Gauge Battery Charging LightIdler Switch Engine ProtectionWire Feeder Voltmeter Switch Weld Mode Selector SwitchWelding Terminals Switch PIN ConnectorBattery Jump Start Terminal VRD Operation Indicator Welding Power SourcesSafety What are VRD and Rocv DEVICES?Typical Fuel Consumption Starting TechniqueBREAK-IN Period Table B.1 Cummins B3.3 Engine Fuel ConsumptionTouch Start TIG Mode Stick Welding ModeCC-STICK Mode Welder OperationCarbon Diameter Current Range DC, elec Trode positive Wire WELDING-CVARC Gouging Table B.3 Typical Current RangesAuxiliary Power Operation Simultaneous Welding and Auxiliary Power LoadsParalleling Accessories Optional Field Installed AccessoriesTIG Options Engine Maintenance MaintenanceRoutine and Periodic Maintenance Daily WeeklyService Instructions Preventing Battery Buckling Battery HandlingPreventing Battery Discharge Fuel FiltersWelder / Generator MAINTE- Nance Troubleshooting HOW to USE Troubleshooting GuideAuthorized Field Service Facility Contact your local LincolnTroubleshooting PCB Wiring Diagram Diagrams Engine Welders / K867 / K775 / LN-7 Connection Diagram To Work Electrode Cable To Wire Feed UnitDiagrams Diagrams Engine Welders / K867 / LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Dimension Print 736 634 24 .97Precaucion Warnung