6 F 3 B 0 3 6 2

 

 

 

 

 

 

Table 4.5 Detailed Information (Ethernet Port Error Responses) PART1

 

 

 

 

 

 

Error

Code

Description

 

 

 

 

 

 

Normal complete

0001H

Request completed normally

 

 

 

 

 

 

Local port fault

0002H

The local port is in down mode

 

 

 

 

 

 

Local port standby

0003H

In standby mode data transmission (socket interface transmission or PC link

 

 

 

protocol transmission) was requested.

 

 

 

 

 

 

Timeout

0020H

Timeout occurred during TCP open processing or receive processing, or during

 

 

 

UDP receive processing.

 

 

 

 

 

 

Length error

0030H

Incorrect send data length

 

 

 

 

 

 

Port mode error

0040H

One of the following requests was issued in a mode other than standby mode:

 

 

 

a. Parameter setup, b. MAC address setup, c. Reset

 

 

 

 

 

 

MAC/IP not set up

0050H

Occurs if the MAC address or IP address is not set up.

 

 

 

 

 

 

Transmission prohibited state

0060H

• Occurs if a PC link request was issued from the T2N in run mode in the

 

 

 

message transmission prohibited state.

 

 

 

• Occurs if a socket open, close, send, or receive request is issued by the T2N

 

 

 

in run mode in the socket interface transmission prohibited state.

 

 

 

 

 

 

Format error

0070H

Occurs when there is a format error in the request text.

 

 

 

 

 

 

 

0071H

Port number error

 

 

 

 

 

 

 

0072H

Request code error

 

 

 

 

 

 

 

0073H

Time setting: Year

 

 

 

 

 

 

 

0074H

Time setting: Month

 

 

 

 

 

 

 

0075H

Time setting: Day

 

 

 

 

 

 

 

0076H

Time setting: Hour

 

 

 

 

 

 

 

0077H

Time setting: Minute

 

 

 

 

 

 

 

0078H

Time setting: Second

 

 

 

 

 

 

Opened

0080H

Occurs if an open request is issued for an already open socket.

 

 

 

 

 

 

Unopened

0081H

• Occurs if send, receive, or close request is issued for an unopened socket.

 

 

 

• Occurs if send, receive request is issued for TCP socket during receiving

 

 

 

CLOSE request (RCLOSE bit is 1).

 

 

 

 

 

 

Incorrect socket identifier

0082H

Occurs if the socket identifier is out of range (1 to 8).

 

 

 

 

 

 

Incorrect control request

0083H

Occurs if a request that was prohibited by an operating mode control request is

 

specification

 

issued.

 

 

 

• Occurs if a run request is issued in run mode.

 

 

 

• Occurs if a standby request is issued in standby mode.

 

 

 

• Occurs if a run request and a standby request are issued at the same time.

 

 

 

 

 

 

LAN controller driver error

0090H

Occurs if the setting of the local port IP address and port number in the area

 

 

 

reserved for transmission fails.

 

 

 

0091H

• Error in the TCP or UDP protocol (such as a transmission phase error)

 

 

 

• Occurs if send request is issued for TCP socket that remote port is down and

 

 

 

NOACK bit is 1.

 

 

 

0092H

• Occurs if the setting of the remote port IP address in the remote port

 

 

 

information area (the NETDATA table) fails.

 

 

 

• Occurs if the remote port IP address network address differs from the local

 

 

 

port IP address network address.

 

 

 

 

 

37

Page 38
Image 38
Toshiba T2N instruction manual Detailed Information Ethernet Port Error Responses PART1, Error Code Description