6 F 3 B 0 3 6 2

For the T/C registers, the data length will be between 1 and 323 words.

(2)Local port register type code

This code indicates the type of register in which the local port transmission source data is stored. See figure 5.1 for the codes that can be specified.

(3)Local port register number

Specifies the starting number of the register specified by the local port register type code.

(4)Remote port register type code

This code specifies the type of the register at the remote port to which the transmitted data will be written. See figure 5.1 for the codes that can be specified.

(5)Remote port register number

Specifies the starting number of the register specified by the remote port register type code.

(6)Timer count

Specifies a time used to limit the response time from the remote port in 0.1 second units.

F E

0

A+10

0:Use the user-specified value (0.1 to 3276.7 seconds)

1:Use the default value of 30 seconds.

Figure 5.1 indicates the register type code that the local or remote port can specify the code. See “T-series Instruction Set (Ladder, SFC)” (UM-TS03***-E004).

RID

Meaning

 

RID

Meaning

 

 

 

 

 

 

*1

0000H

XW/YW registers

 

∗∗05H

F register (0 - 8191)

 

 

 

 

 

*2

0001H

W register

 

∗∗06H

F register (0 - 65535)

 

 

 

 

 

*3

0002H

LW register

 

0007H

T register

 

 

 

 

 

*3

0003H

RW register

 

0008H

C register

 

 

 

 

 

 

0004H

D register

 

0009H

SW register

 

 

 

 

 

 

 

Figure 5.1 Register Type Code

*1 Includes the expansion F registers. One bank has 8k words (0 to 8191).

F 7 0

05H

Bank number ... 00H: T2N internal registers

F0000 to F1023

01H to 03H: Expansion F registers

F0000 to F8191

58

Page 59
Image 59
Toshiba T2N instruction manual Rid