6 F 3 B 0 3 6 2
1.4 Ethernet Port Specifications
Table 1.2 lists the Ethernet Port specifications. The general specifications of the Ethernet Port conform to those of the T2N main unit.
|
| Table 1.2 Functional Specifications | |||
|
|
|
| ||
Item |
| Specification | |||
|
|
|
| ||
Module type |
| PU235N/245N (Ethernet Port is | |||
|
|
|
| ||
Transmission |
|
| |||
specifications |
|
|
|
|
|
|
|
|
| ||
| Media access method |
| CSMA/CD | ||
|
|
|
| ||
| Modulation |
| Baseband | ||
|
|
|
| ||
| Transmission topology |
| Bus type | ||
|
|
|
| ||
| Transmission speed |
| 10 Mbps | ||
|
|
|
| ||
| Maximum distance between |
| 200 m (Case of single HUB) | ||
| ports |
| 1700 m (Case of four HUB) | ||
|
|
| |||
| Maximum segment length |
| 100 m (Between port and HUB) | ||
| Maximum number of ports |
| single port per segment | ||
|
|
|
|
| |
| Minimum port separation |
| None |
| |
|
|
|
| ||
| Connector |
| |||
|
|
|
| ||
| Connecting cable |
| Unshield twisted pair | ||
|
|
|
|
| |
Transmission services |
| 1. | T series computer link protocol (slave port) | ||
|
|
| 2. | T series/PC link protocol | |
|
|
| 3. | Socket interface (8 sockets) | |
|
|
| 4. | PC gateway function (currently unsupported) | |
|
|
|
| ||
RAS functions |
| 1. | Self diagnostics at power on | ||
|
|
|
| ROM, RAM, LAN controller, EEPROM, | |
|
|
|
| T2N interface buffer memory, MAC address | |
|
|
| 2. | Test functions accessible from user programs | |
|
|
|
| • Remote port verification request | |
|
|
|
| • Remote port loopback test (Between T2N and T2N/T3H systems) | |
|
|
| 3. | Data provided by RAS data readout | |
|
|
|
| • | Event trace |
|
|
|
| • LAN controller (network) information | |
|
|
|
| • | Protocol state |
|
|
| 4. | Time/date setup function | |
|
|
| 5. | Station status in the T2N special registers (SW) | |
|
|
| 6. | Socket information in the T2N interface buffer | |
|
|
| |||
Consumed current [A] |
| 0.6A (5V DC) | |||
|
|
| |||
External dimensions [mm] |
| 99.0 (W) ×122 (H) | |||
Weight [grams] |
| 200 |
|
| |
Mounting method |
| ||||
Number of modules mountable |
| 1 modules per T2N | |||
|
|
| |||
Access method |
| SEND/RECV instructions (module control and transmission functions) | |||
|
|
|
|
|
|
*Segment: A network unit formed from a single transmission medium (twisted pair cable)
⎯ 21 ⎯