Lincoln Electric IM10044 manual PRE-OPERATION Engine and COM- Pressor Service, Oil, Fuel CAP

Page 14

A-4

INSTALLATION

A-4

 

 

 

PRE-OPERATION ENGINE AND COM- PRESSOR SERVICE

READ the engine and compressor operating and maintenance instructions supplied with this machine.

WARNING

• Keep hands away from the engine muffler or HOT engine parts.

Stop engine and allow to cool before fuelling.

Do not smoke when fuelling.

Fill fuel tank at a moderate rate and do not over- fill.

Wipe up spilled fuel and allow fumes to clear before starting engine.

Keep sparks and flame away from tank.

------------------------------------------------------------------------

OIL

The VANTAGE® 575 CUMMINS is shipped with the engine crankcase filled with high quality SAE 10W-30 oil (API class CD or better). Check the engine and compressor oil levels before starting the engine. If it is not up to the full mark on the dip stick, add oil as required. Check the oil level every four hours of run- ning time during the first 35 running hours. Refer to the engine Operator’s Manuals for specific oil recom- mendations and break-in information. The oil change interval is dependent on the quality of the oil and the operating environment. Refer to the engine Operator’s Manuals for the proper service and maintenance inter- vals.

FUEL USE DIESEL FUEL ONLY

Fill the fuel tank with clean, fresh diesel fuel. The capacity of the fuel tank is approximately 25 gallons (95 liters). See engine Operator’s Manual for specif- ic fuel recommendations. Running out of fuel may require bleeding the fuel injection pump.

NOTE: Before starting the engine, open the fuel shut- off valve (pointer to be in line with hose).

FUEL CAP

Remove the plastic cap covering from the Fuel Tank Filler neck and install the Fuel Cap.

ENGINE COOLANT

WARNING

HOT COOLANT can burn skin.

•Do not remove cap if radiator is hot.

------------------------------------------------------------------------

The welder is shipped with the engine and radiator filled with a 50% mixture of ethylene glycol and water. See the MAINTENANCE section and the engine Operator’s Manual for more information on coolant.

BATTERY CONNECTION

WARNING

GASES FROM BATTERY can explode.

• Keep sparks, flame and cigarettes away from battery.

To prevent EXPLOSION when:

INSTALLING A NEW BATTERY — disconnect negative cable from old battery first and connect to new battery last.

CONNECTING A BATTERY CHARGER — remove battery from welder by disconnecting negative cable first, then positive cable and battery clamp. When reinstalling, connect negative cable last. Keep well ventilated.

USING A BOOSTER — connect positive lead to battery first then connect negative lead to nega- tive battery lead at engine foot.

BATTERY ACID can burn eyes and skin.

• Wear gloves and eye protection and be careful when working near battery.

• Follow instructions printed on battery.

------------------------------------------------------------------------

IMPORTANT: To prevent ELECTRICAL DAMAGE WHEN:

a)Installing new batteries.

b)Using a booster.

Use correct polarity — Negative Ground.

VANTAGE® 575 CUMMINS

Image 14
Contents Vantage Cummins Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcElectromagnetic Compatibility EMC Safety Thank You Table of Contents Table of Contents Installation Storing Safety PrecautionsLocation and Ventilation StackingHigh Altitude Operation High Temperature OperationLifting TowingOIL PRE-OPERATION Engine and COM- Pressor ServiceBattery Connection Fuel USE Diesel Fuel onlySpark Arrestor AIR Cleaner Inlet HoodMuffler Outlet Pipe Welding TerminalsStandby Power Connections Remote ControlAuxiliary Power Receptacles Across The-Arc Model Connection of Lincoln ELEC- Tric Wire FeedersConnection of LN-15 to the Vantage 575 CUM Control Cable ModelConnection of the LN-25 to the VAN- Tage 575 Cummins Shut off welder before making any electrical con- nectionsGeneral Description Safety PrecautionsOperation Recommended ApplicationsControls and Settings OIL Pressure Gauge Battery Charging LightIdler Switch Engine ProtectionWire Feeder Voltmeter Switch Weld Mode Selector SwitchWelding Terminals Switch PIN ConnectorBattery Jump Start Terminal VRD Operation Indicator Welding Power SourcesSafety What are VRD and Rocv DEVICES?Typical Fuel Consumption Starting TechniqueBREAK-IN Period Table B.1 Cummins B3.3 Engine Fuel ConsumptionTouch Start TIG Mode Stick Welding ModeCC-STICK Mode Welder OperationCarbon Diameter Current Range DC, elec Trode positive Wire WELDING-CVARC Gouging Table B.3 Typical Current RangesParalleling Auxiliary Power OperationSimultaneous Welding and Auxiliary Power Loads TIG Options AccessoriesOptional Field Installed Accessories Engine Maintenance MaintenanceRoutine and Periodic Maintenance Daily WeeklyService Instructions Preventing Battery Buckling Battery HandlingPreventing Battery Discharge Fuel FiltersWelder / Generator MAINTE- Nance Troubleshooting HOW to USE Troubleshooting GuideAuthorized Field Service Facility Contact your local LincolnTroubleshooting PCB Wiring Diagram Diagrams Engine Welders / K867 / K775 / LN-7 Connection Diagram To Work Electrode Cable To Wire Feed UnitDiagrams Diagrams Engine Welders / K867 / LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Dimension Print 736 634 24 .97Precaucion Warnung