Lincoln Electric IM10044 Lifting, High Altitude Operation, High Temperature Operation, Towing

Page 13

A-3

INSTALLATION

A-3

 

 

 

LIFTING

The VANTAGE® 575 CUMMINS lift bale should be used to lift the machine. The VANTAGE® 575 CUM- MINS is shipped with the lift bale retracted. Before attempting to lift the VANTAGE® 575 CUMMINS the lift bale must be secured in a raised position. Secure the lift bale as follows:

a. Open the engine compartment door.

b. Locate the 2 access holes on the upper middle region of compartment wall just below the lift bale.

c. Use the lifting strap to raise the lift bale to the full upright position. This will align the mount- ing holes on the lift bale with the access holes.

d. Secure the lift bale with 2 thread forming screws . The screws are provided in the shipped loose parts bag.

WARNING

• Lift only with equipment of ade- quate lifting capacity.

• Be sure machine is stable when lift-

 

ing.

 

• Do not lift this machine using lift

 

bail if it is equipped with a heavy

 

accessory such as trailer or gas

 

cylinder.

FALLING

• Do not lift machine if lift bail is

EQUIPMENT can

damaged.

cause injury.

• Do not operate machine while

 

suspended from lift bail.

------------------------------------------------------------------------

HIGH ALTITUDE OPERATION

At higher altitudes, output derating may be necessary. For maximum rating, derate the welder output 4% for every 300 meters (984 ft.) above 1500 meters (4920 ft.). For output of 500A and below, derate the welder output 4% for every 300 meters (984 ft.) above 2100 meters (6888 ft.).

Contact a Cummins Service Representative for any engine adjustments that may be required.

HIGH TEMPERATURE OPERATION

At temperatures above 40°C (104°F), output voltage derating may be necessary. For maximum output cur- rent ratings, derate welder voltage rating 2 volts for every 10°C (21°F) above 40°C (104°F).

TOWING

The recommended trailer for use with this equipment for road, in-plant and yard towing by a vehicle (1) is Lincoln’s K2636-1. If the user adapts a non-Lincoln trailer, he must assume responsibility that the method of attachment and usage does not result in a safety hazard nor damage the welding equipment. Some of the factors to be considered are as follows:

1.Design capacity of trailer vs. weight of Lincoln equipment and likely additional attachments.

2.Proper support of, and attachment to, the base of the welding equipment so that there will be no undue stress to the trailer’s framework.

3.Proper placement of the equipment on the trailer to insure stability side to side and front to back when being moved and when standing by itself.

4.Typical conditions of use, such as travel speed, roughness of surface on which the trailer will be operated, and environmental conditions.

5.Proper preventative maintenance of trailer.

6.Conformance with federal, state and local laws (1) .

(1)Consult applicable federal, state and local laws regarding specific requirements for use on public highways.

VEHICLE MOUNTING

WARNING

Improperly mounted concentrated loads may cause unstable vehicle handling and tires or other components to fail.

Only transport this Equipment on serviceable vehicles which are rated and designed for such loads.

Distribute, balance and secure loads so vehicle is stable under conditions of use.

Do not exceed maximum rated loads for compo- nents such as suspension, axles and tires.

Mount equipment base to metal bed or frame of vehicle.

Follow vehicle manufacture’s instructions.

------------------------------------------------------------------------

VANTAGE® 575 CUMMINS

Image 13
Contents Vantage Cummins California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéElectromagnetic Compatibility EMC Safety Thank You Table of Contents Table of Contents Installation Location and Ventilation Safety PrecautionsStoring StackingLifting High Temperature OperationHigh Altitude Operation TowingBattery Connection PRE-OPERATION Engine and COM- Pressor ServiceOIL Fuel USE Diesel Fuel onlyMuffler Outlet Pipe AIR Cleaner Inlet HoodSpark Arrestor Welding TerminalsAuxiliary Power Receptacles Remote ControlStandby Power Connections Connection of LN-15 to the Vantage 575 CUM Connection of Lincoln ELEC- Tric Wire FeedersAcross The-Arc Model Control Cable ModelShut off welder before making any electrical con- nections Connection of the LN-25 to the VAN- Tage 575 CumminsOperation Safety PrecautionsGeneral Description Recommended ApplicationsControls and Settings Idler Switch Battery Charging LightOIL Pressure Gauge Engine ProtectionWelding Terminals Switch Weld Mode Selector SwitchWire Feeder Voltmeter Switch PIN ConnectorBattery Jump Start Terminal Safety Welding Power SourcesVRD Operation Indicator What are VRD and Rocv DEVICES?BREAK-IN Period Starting TechniqueTypical Fuel Consumption Table B.1 Cummins B3.3 Engine Fuel ConsumptionCC-STICK Mode Stick Welding ModeTouch Start TIG Mode Welder OperationARC Gouging Wire WELDING-CVCarbon Diameter Current Range DC, elec Trode positive Table B.3 Typical Current RangesSimultaneous Welding and Auxiliary Power Loads Auxiliary Power OperationParalleling Optional Field Installed Accessories AccessoriesTIG Options Routine and Periodic Maintenance Daily MaintenanceEngine Maintenance WeeklyService Instructions Preventing Battery Discharge Battery HandlingPreventing Battery Buckling Fuel FiltersWelder / Generator MAINTE- Nance HOW to USE Troubleshooting Guide TroubleshootingContact your local Lincoln Authorized Field Service FacilityTroubleshooting PCB Wiring Diagram Diagrams To Work Electrode Cable To Wire Feed Unit Engine Welders / K867 / K775 / LN-7 Connection DiagramDiagrams Diagrams Engine Welders / K867 / LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams 736 634 24 .97 Dimension PrintPrecaucion Warnung