Lincoln Electric IM10044 manual Safety, California Proposition 65 Warnings

Page 2

i

SAFETY

i

WARNING

CALIFORNIA PROPOSITION 65 WARNINGS

Diesel engine exhaust and some of its constituents are known to the State of California to cause can- cer, birth defects, and other reproductive harm.

The Above For Diesel Engines

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

The Above For Gasoline Engines

ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.

FOR ENGINE powered equipment.

1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.

____________________________________________________

1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.

____________________________________________________

1.c. Do not add the fuel near an open flame welding arc or when the engine is running. Stop the engine and allow it to cool before refueling to prevent spilled fuel from vaporiz- ing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.

____________________________________________________

1.d. Keep all equipment safety guards, covers and devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.

____________________________________________________

1.e. In some cases it may be necessary to remove safety g u a r d s t o p e r f o r m r e q u i r e d m a i n t e n a n c e . R e m o v e guards only when necessary and replace them when the m a i n t e n a n c e r e q u i r i n g t h e i r r e m o v a l i s c o m p l e t e . Always use the greatest care when working near moving parts.

___________________________________________________

1.f. Do not put your hands near the engine fan. Do not attempt to override the governor or idler by pushing on the throttle control rods while the engine is running.

___________________________________________________

1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.

1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.

ELECTRIC AND MAGNETIC FIELDS may be dangerous

2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines

2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.

2.c. Exposure to EMF fields in welding may have other health effects which are now not known.

2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Secure them with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode and work cables. If the electrode cable is on your right side, the work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.

2.d.5. Do not work next to welding power source.

Mar ‘95

Image 2
Contents Vantage Cummins Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcElectromagnetic Compatibility EMC Safety Thank You Table of Contents Table of Contents Installation Storing Safety PrecautionsLocation and Ventilation StackingHigh Altitude Operation High Temperature OperationLifting TowingOIL PRE-OPERATION Engine and COM- Pressor ServiceBattery Connection Fuel USE Diesel Fuel onlySpark Arrestor AIR Cleaner Inlet HoodMuffler Outlet Pipe Welding TerminalsStandby Power Connections Remote ControlAuxiliary Power Receptacles Across The-Arc Model Connection of Lincoln ELEC- Tric Wire FeedersConnection of LN-15 to the Vantage 575 CUM Control Cable ModelConnection of the LN-25 to the VAN- Tage 575 Cummins Shut off welder before making any electrical con- nectionsGeneral Description Safety PrecautionsOperation Recommended ApplicationsControls and Settings OIL Pressure Gauge Battery Charging LightIdler Switch Engine ProtectionWire Feeder Voltmeter Switch Weld Mode Selector SwitchWelding Terminals Switch PIN ConnectorBattery Jump Start Terminal VRD Operation Indicator Welding Power SourcesSafety What are VRD and Rocv DEVICES?Typical Fuel Consumption Starting TechniqueBREAK-IN Period Table B.1 Cummins B3.3 Engine Fuel ConsumptionTouch Start TIG Mode Stick Welding ModeCC-STICK Mode Welder OperationCarbon Diameter Current Range DC, elec Trode positive Wire WELDING-CVARC Gouging Table B.3 Typical Current RangesParalleling Auxiliary Power OperationSimultaneous Welding and Auxiliary Power Loads TIG Options AccessoriesOptional Field Installed Accessories Engine Maintenance MaintenanceRoutine and Periodic Maintenance Daily WeeklyService Instructions Preventing Battery Buckling Battery HandlingPreventing Battery Discharge Fuel FiltersWelder / Generator MAINTE- Nance Troubleshooting HOW to USE Troubleshooting GuideAuthorized Field Service Facility Contact your local LincolnTroubleshooting PCB Wiring Diagram Diagrams Engine Welders / K867 / K775 / LN-7 Connection Diagram To Work Electrode Cable To Wire Feed UnitDiagrams Diagrams Engine Welders / K867 / LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Dimension Print 736 634 24 .97Precaucion Warnung