OPERATION | ||
|
|
|
23. 415 VAC RECEPTACLE
This is a 415VAC receptacle that provides auxil- iary power. This receptacle has 32 amp rating and IP66 rated . Refer to the AUXILIARY POWER RECEPTACLES section in the installa- tion chapter for further information about these receptacles . Also refer to the AUXILIARY POWER OPERATION section later in this chap- ter.
24. GROUND STUD:
Provides a connection point for connecting the machine case to earth ground . Refer to “MACHINE GROUNDING” in the Installation chapter for proper machine grounding informa- tion.
25. RCD:
“Residual Current Device” provides protection from active to ground contact.
RCD will not protect against electrical shock resulting from contact with active and neutral wires.
26. VRD INDICATOR LIGHTS:
Indicates OCV voltage across the output termi- nals. Also indicates operation of VRD in CC mode. A Green light indicates OCV below 30V and a red light indicates OCV above 30V.
During welding both lights will flash, depending on the type of Consumable being used.
BATTERY JUMP START TERMINAL (27-28)
27.POSITIVE BATTERY JUMP START TERMINAL.
28.NEGATIVE BATTERY JUMP START TERMINAL.
12V battery jump start feature is standard . Covered output studs for convenient access, and protection against accidental impact. can be used to
29. BATTERY DISCONNECT SWITCH
Battery disconnect switch provides lockout/tagout capability. Switch is conveniently located on the front bottom of the machine.
30. AIR CLEANER SERVICE INDICATOR
Air cleaner service indicator provides a
FIGURE B.2
30