23)Drive three (3) self-tapping screws into output panel. (5/16” Nut driver or socket wrench). NOTE: The CV outout terminal assembly mounts under the weld output terminals on all machines.

24)With the CC/CV switch set to CC, start the engine and check the open circuit voltage on the output terminals. The voltage should be 80 to 100 volts with the thermostat and range switch set at maxi- mum. NOTE: OCV may be slightly higher when the unit is cold. (Voltmeter)

25)Switch the CC/CV switch to CV and check the voltage between the Positive output terminal and the CV output terminal. The voltage should be 45 to 55 volts at maximum output position and 7 to 12 volts at minimum output position. (Voltmeter)

26)(For Classic II’s only) Reassemble the side panel. (3/8” Socket wrench)

– 15 –

Image 15
Contents Safety Depends on You Wire Feed ModuleSafety Electric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionPrécautions DE Sûreté IvSAFETYThank You Table of Contents General Description SpecificationsDesign Features Recommended Wire Feeders and AccessoriesMoving Parts can injure Installation InstructionsPre Installation Engine Exhaust can killFor codes 10066 Tion SequencePage Page Page Page Page For Code Assembly Into SAE-300 Welder Installation SequencePage Page Connection of Lincoln Electric Wire Feeders Connection of the LN-7, LN-7 GMA to the Wire Feed ModuleConnection of the LN-23P to the Wire Feed Module Operating Instructions MaintenanceTroubleshooting Chart Wire Feed Module OperationTrouble Causes What to do TroubleshootingTroubleshooting Procedure for Checking the Cold Tip Contactor CR4 Troubleshooting ProceduresC. Board Troubleshooting Procedures Procedures for Replacing P.C. BoardsProcedure for Checking the Capacitor Bank Contactor CR3 Remote Control CheckChecking Voltage Control Potentiometer on Machine Quick Check Procedure for Generator Only Wire Feed Module Wiring Diagram Engine Welder M17323 1 0 3 1 0 3 Engine Welder Engine Welder Engine Welder with + CV Classic I and Pipeliner 200D and 200G with Wire Feed Module = Wire Feeder OCV Volts Load Classic II with Wire Feed ModuleClassic III and 300G with Wire Feed Module = Wire Feeder OCV Volts Load Load Amps DC SA and SA-250 Codes 10889 and below with Wire Feed ModuleWire Feed Module Wire Feed Module Precaucion Warnung