WIRE FEED MODULE / ENGINE WELDER CONNECTION DIAGRAM
ENGINE WELDER
CONNECTOR
|
| JUMPER PLUG | |
| INLINE | W . F . M . | |
| CONNECTORS | ||
W . F . M . | PLUG | ||
| |||
|
| ||
CONTROL |
|
| |
PANEL |
|
|
ON ENGINE WELDER REMOVE JUMPER PLUG FROM CONNECTOR AND CONNECT W . F . M . PLUG TO CONNECTOR ON ENGINE WELDER .
– 27 –
| #8 | LEAD | WIRE FEED |
CONNECT TO POS . & NEG . | POS . |
| |
OUTPUT TERMINALS | NEG . |
| MODULE |
|
| ||
NEGATIVE CV | #2 HEAVY LEAD | ||
OUTPUT TERMINAL |
| ||
PANEL | 608 609 |
|
|
CONNECT TO NEG . |
|
| |
|
|
| |
BRUSH HOLDER | #2 HEAVY LEAD |
| |
|
| ||
THERMOSTAT |
|
| |
ASSEMBLY |
|
|
|
CAUTION: THIS UNIT IS PREASSEMBLED WITH A 250 AMP THERMOSTAT ASSEMBLY. INSTALLING THIS UNIT INTO A CLASSIC 1 OR ANY 200 AMP MACHINE REQUIRES REPLACEMENT OF THE 250 AMP THERMOSTAT AS'BLY WITH THE 200 AMP THERMOSTAT AS'BLY PROVIDED IN THE MOUNTING HARDWARE PACKET.
*MACHINE MUST NOT BE RUNNING WHEN MAKING THESE CONNECTIONS .
3 - 1 8 - 9 4
M 1 7 2 2 0
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number.
–