ASSEMBLY INTO SAE-300 WELDER: INSTALLATION SEQUENCE:

(For Code 11806 )

1.Remove the bottom 3 mounting screws from the upper control nameplate. Keep the screws for later use to fasten the WFM nameplate. Once, the screws have been removed snap / break off the lower section of the nameplate (the section with the welder name on it).

1. Remove 3 mounting screws.

2.Snap or Break off lower section on this dotted line.

2.Attach the WFM nameplate to the upper control panel on the welder below the original nameplate with 5 mounting screws.

5 mounting screws.

5.Remove 2 screws from brush wraparound cover. Loosen and rotate the wraparound cover until neg- ative brushholder is exposed. (Large flat head screwdriver and pliers).

6.The negative brushholder is in the 11:00 position looking at the control panel end of the generator. Remove negative brushholder 5/16” bolt. (1/2” Socket, ratchet, and small extension.)

3.Remove the 2 toggle switches, amphenol & cap and the potentiometer with knob from the original control panel assembly. DO NOT disconnect the wiring from the switches.

4.Insert the local / remote toggle switch (most wires connected to it) first into the upper control panel on the welder with the mounting tab down. Next mount the potentiometer and secure the knob. Next mount the cv / cc toggle switch with the mounting tab down. Mount the amphenol and cap.

7.Position Wire Feed Module control box next to the right side of the machine (as shown). Place one plain washer (provided in the mounting hardware packet) over each mounting stud.

– 16 –

Image 16
Contents Wire Feed Module Safety Depends on YouSafety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiIvSAFETY Précautions DE SûretéThank You Table of Contents Specifications Design FeaturesRecommended Wire Feeders and Accessories General DescriptionInstallation Instructions Pre InstallationEngine Exhaust can kill Moving Parts can injureTion Sequence For codes 10066Page Page Page Page Page Assembly Into SAE-300 Welder Installation Sequence For CodePage Page Connection of the LN-7, LN-7 GMA to the Wire Feed Module Connection of Lincoln Electric Wire FeedersConnection of the LN-23P to the Wire Feed Module Maintenance Troubleshooting ChartWire Feed Module Operation Operating InstructionsTroubleshooting Trouble Causes What to doTroubleshooting Troubleshooting Procedures C. Board Troubleshooting ProceduresProcedures for Replacing P.C. Boards Procedure for Checking the Cold Tip Contactor CR4Remote Control Check Procedure for Checking the Capacitor Bank Contactor CR3Checking Voltage Control Potentiometer on Machine Quick Check Procedure for Generator Only Wire Feed Module Wiring Diagram Engine Welder M17323 1 0 3 1 0 3 Engine Welder Engine Welder Engine Welder with + CV Classic I and Pipeliner 200D and 200G with Wire Feed Module Classic II with Wire Feed Module = Wire Feeder OCV Volts LoadClassic III and 300G with Wire Feed Module = Wire Feeder OCV Volts Load SA and SA-250 Codes 10889 and below with Wire Feed Module Load Amps DCWire Feed Module Wire Feed Module Precaucion Warnung