Lincoln Electric IM 513-B manual Quick Check Procedure for Generator Only

Page 25

H.Quick Check Procedure for Generator Only

1.Try running the machine with the mode switch on STICK (CC mode), and check output at CC+ and CC- studs. If a voltage of 45 to 100 volts DC is measured, the generator is working properly. If the gen- erator is working properly, the problem exists in the Wire Feed Module. Refer to Troubleshooting chart.

2.If there is no generator output in step 1, proceed with the following:

a)If jumper plug P10 is available, a quick check can be performed to see if the generator is operating properly. Disconnect P5 and connect P10. When P10 is connected, the machine will only run in Stick (CC mode). If generator voltage is present between CC+ and CC- studs, then the genera- tor is operating properly.

b)The measured voltage should be between 43-100 volts DC. This level may be higher when the machine is cold. If the generator is operating properly, disconnect P10 and recon- nect P5. Refer to Wire Feed Module Troubleshooting chart.

3.If the generator is not working with the jumper plug P10, then refer to the engine welder Troubleshooting chart.

– 25 –

Image 25
Contents Safety Depends on You Wire Feed ModuleSafety Electric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionPrécautions DE Sûreté IvSAFETYThank You Table of Contents Design Features SpecificationsRecommended Wire Feeders and Accessories General DescriptionPre Installation Installation InstructionsEngine Exhaust can kill Moving Parts can injureFor codes 10066 Tion SequencePage Page Page Page Page For Code Assembly Into SAE-300 Welder Installation SequencePage Page Connection of the LN-7, LN-7 GMA to the Wire Feed Module Connection of Lincoln Electric Wire FeedersConnection of the LN-23P to the Wire Feed Module Troubleshooting Chart MaintenanceWire Feed Module Operation Operating InstructionsTrouble Causes What to do TroubleshootingTroubleshooting C. Board Troubleshooting Procedures Troubleshooting ProceduresProcedures for Replacing P.C. Boards Procedure for Checking the Cold Tip Contactor CR4Remote Control Check Procedure for Checking the Capacitor Bank Contactor CR3Checking Voltage Control Potentiometer on Machine Quick Check Procedure for Generator Only Wire Feed Module Wiring Diagram Engine Welder M17323 1 0 3 1 0 3 Engine Welder Engine Welder Engine Welder with + CV Classic I and Pipeliner 200D and 200G with Wire Feed Module = Wire Feeder OCV Volts Load Classic II with Wire Feed ModuleClassic III and 300G with Wire Feed Module = Wire Feeder OCV Volts Load Load Amps DC SA and SA-250 Codes 10889 and below with Wire Feed ModuleWire Feed Module Wire Feed Module Precaucion Warnung