INSTALLATION | ||
|
|
|
CONNECTION OF LINCOLN ELEC- TRIC WIRE FEEDERS
WARNING
Shut off welder before making any electrical con- nections.
Connection of
1.Shut the welder off.
2.Connect the
3.Set the "WIRE FEEDER VOLTMETER" switch to either "+" or
4.Set the "MODE" switch to the "CV WIRE " posi- tion.
5.Set the "ARC CONTROL" knob to "0" initially and adjust to suit.
6.Set the "WELD TERMINALS" switch to the "REMOTELY CONTROLLED" position.
7.Set the "IDLE" switch to the "HIGH" position.
Connection of LN-15 to the AIR VANTAGE® 500 (AU)
These connections instructions apply to both the LN-
15
1.Shut the welder off.
2.For electrode Positive, connect the electrode cable to the "+" terminal of the welder and work cable to the
3.Across The-Arc Model:
•Set the "WELD TERMINALS" switch to "WELD
TERMINALS ON".
•When the gun trigger is closed, the current sens- ing circuit will cause the AIR VANTAGE® 500 (AU) engine to go to the high idle speed, the wire will begin to feed and the welding process start- ed. When welding is stopped, the engine will revert to low idle speed after approximately 12 seconds unless welding is resumed.
4.Control Cable Model:
•Connect Control Cable between Engine Welder and Feeder.
•Set the "WELD TERMINALS" switch to
"REMOTELY CONTROLLED"
•Set the MODE switch to the
•Set the "WIRE FEEDER VOLTMETER" switch to either "+" or
•Set the "ARC CONTROL" knob to "0" initially and adjust to suit.
•Set the "IDLE" switch to the "AUTO" position.
•When the gun trigger is closed, the current sens- ing circuit will cause the AIR VANTAGE® 500 (AU) engine to go to the high idle speed, the wire will begin to feed and the welding process start- ed. When welding is stopped, the engine will revert to low idle speed after approximately 12 seconds unless welding is resumed.
•Attach the single lead from the front of the
AIR VANTAGE® 500 (AU)