b-8

OPERATION

b-8

 

 

 

WELDER OPERATION

DUTY CYCLE

Duty Cycle is the percentage of time the load is being applied in a 10 minute period. For example a 60% duty cycle, represents 6 minutes of load and 4 minutes of no load in a 10 minute period.

STICK WELDING MODE

The AIR VANTAGE® 500 (AU) can be used with a broad range of DC stick electrodes. The MODE switch provides two stick welding settings as follows:

CC-STICK MODE

The CC-STICK position of the MODE switch is designed for horizontal, vertical-up and over head welding with all types of electrodes, especially low hydrogen. The OUTPUT CONTROL knob adjusts the full output range for stick welding.

The ARC CONTROL knob sets the short circuit (arc- force) current during stick welding. Increasing the number from -10(Soft) to +10(Crisp) increases the short circuit current and prevents sticking of the elec- trode to the plate while welding. This can also increase spatter. It is recommended that the ARC CONTROL be set to the minimum number without electrode sticking. Start with the knob set at 0.

TOUCH START TIG MODE

The AIR VANTAGE® 500 (AU) can be used in a wide variety of DC TIG welding applications.

The TOUCH START TIG setting of the MODE switch is for DC TIG (Tungsten Inert Gas) welding. To initiate a weld, the OUTPUT CONTROL knob is first set to the desired current and the tungsten is touched to the work. During the time the tungsten is touching the work there is very little voltage or current and, in gen- eral, avoids tungsten contamination. Then, the tung- sten is gently lifted off the work in a rocking motion, which establishes the arc.

To stop the arc, simply lift the TIG torch away from the work piece. When the arc voltage reaches approxi- mately 30 volts, the arc will go out and the machine will automatically reset to the touch start current level. The tungsten may then be retouched to the work piece to restrike the arc. The arc may also be started and stopped with an Amptrol or Arc Start Switch.

The ARC CONTROL is not active in the TIG mode.

In general the ‘Touch Start’ feature avoids tungsten contamination without the use of a Hi-frequency unit. If the use of a high frequency generator is desired, the K930-2 TIG Module can be used with the AIR VAN- TAGE® 500 (AU). The settings are for reference.

The AIR VANTAGE® 500 (AU) is equipped with the required R.F. bypass circuitry for the connection of high frequency generating equipment.

The AIR VANTAGE® 500 (AU) and any high frequen- cy generating equipment must be properly grounded. See the K930-2 TIG Module operating manuals for complete instructions on installation, operation, and maintenance.

When using the TIG Module, the OUTPUT control on the AIR VANTAGE® 500 (AU) is used to set the maxi- mum range of the CURRENT CONTROL on the TIG Module or an Amptrol if connected to the TIG Module.

AIR VANTAGE® 500 (AU) SETTINGS WHEN USING THE K930-2 TIG MODULE

Set the WELD MODE switch to the “Touch Start Tig 20- 250 Setting”.

Set the IDLER switch to the “AUTO” position.

Set the WELDING TERMINALS switch to the “Remotely Controlled” position. This will keep the solid state contactor open and provide a “cold” electrode until the triggering device (Amptrol or Arc Start Switch) is pressed.

AIR VANTAGE® 500 (AU)

Image 26
Contents Safety Depends on You 11656Safety California Proposition 65 WarningsIiSAFETY IiiSAFETY IiiIvSAFETY Précautions DE SûretéElectromagnetic Compatibility EMC Methods of Reducing Emissions Mains Supply On-Line Product Registration ViiPlease Examine Carton and Equipment For Damage Immediately TAbLE of Contents TAbLE of Contents Open Circuit Voltage InstallationDuty Cycle Welding Output Volts at Rated Amps Height Width DepthStoring Safety PrecautionsLocation and Ventilation StackingHigh Altitude Operation High Temperature OperationLifting TowingFuel USE Diesel Fuel only PRE-OPERATION Engine and COM- Pressor ServiceOIL Fuel CAPSpark Arrestor AIR Cleaner Inlet HoodMuffler Outlet Pipe Welding TerminalsSTANDbY Power Connections Remote ControlAuxiliary Power Receptacles Across The-Arc Model Connection of Lincoln ELEC- Tric Wire FeedersConnection of LN-15 to the AIR Vantage 500 AU Control Cable ModelConnection of the LN-25 to the AIR Vantage 500 AU Shut off welder before making any electrical con- nectionsOperation General DescriptionControls and Settings ENGINE PROTECTION Idler SwitchOIL Pressure Gauge Output ControlWire Feeder Voltmeter Switch WELD MODE SELECTOR SWITCHWelding Terminals Switch PIN ConnectorAIR Compressor Controls 26 Thru VRD Operation Indicator Welding Power SourcesSafety What are VRD and Rocv DEVICES?Typical Fuel Consumption Starting TechniqueBREAK-IN Period Table b.1 Cummins b3.3 Engine Fuel ConsumptionTouch Start TIG Mode Stick Welding ModeCC-STICK Mode Welder OperationTable b.3 Typical Current Ranges Wire WELDING-CVARC Gouging Paralleling Auxiliary Power OperationSimultaneous Welding and AUXIL- Iary Power Loads PlusTIG Options AccessoriesOptional Field Installed Accessories K2641-2 Four Wheeled STEERAbLE Yard TrailerMaintenance Compressor MaintenanceService Instructions Single- and Two-StageEngine Air CleanersPreventing Electrical Damage Fuel FiltersCooling System Storage CleaningWelder / Generator MAINTE- Nance Nameplates / Warning Decals MAIN- TenanceTROUbLESHOOTING POSSIbLE PRObLEMSSymptoms Cause Recommended Course of ActionTROUbLESHOOTING Faulty receptacle Wiring Diagram Diagrams Engine Welders / K867 / K775 / LN-7 Connection Diagram To Work Electrode Cable To Wire Feed UnitDiagrams Diagrams Engine Welders / K867 / LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Dimension Print AIR Vantage 500 AU Precaucion Warnung