Lincoln Electric IM992 manual Welding and Cutting Sparks can Cause fire or explosion, Iii

Page 4

iii

SAFETY

iii

WELDING and CUTTING

SPARKS can

cause fire or explosion.

6.a. Remove fire hazards from the welding area. If this is not possible, cover them to prevent the welding sparks from starting a fire.

Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.

6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operating information for the equipment being used.

6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.

6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even though they have been “cleaned”. For information, purchase “Recommended Safe Practices for the Preparation for Welding and Cutting of Containers and Piping That Have Held Hazardous Substances”, AWS F4.1 from the American Welding Society (see address above).

6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.

6.f. Sparks and spatter are thrown from the welding arc. Wear oil free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.

6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate cir- cuits. This can create fire hazards or overheat lifting chains or cables until they fail.

6.h. Also see item 1.c.

6.I. Read and follow NFPA 51B “ Standard for Fire Prevention During Welding, Cutting and Other Hot Work”, available from NFPA, 1 Batterymarch Park, PO box 9101, Quincy, Ma 022690-9101.

6.j. Do not use a welding power source for pipe thawing.

CYLINDER may explode if damaged.

7.a. Use only compressed gas cylinders

containing the correct shielding gas for the process used and properly operating regulators designed for the gas and

pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.

7.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.

7.c. Cylinders should be located:

Away from areas where they may be struck or subjected to physical damage.

A safe distance from arc welding or cutting operations and any other source of heat, sparks, or flame.

7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.

7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.

7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.

7.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.

FOR ELECTRICALLY powered equipment.

8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.

8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.

8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations.

Refer to http://www.lincolnelectric.com/safety for additional safety information.

Image 4
Contents Safety Depends on You VantageSafety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiIvSAFETY Précautions DE SûretéPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTAbLE of Contents Vii Section DSection E Section FHeight Width Depth Weight AIR Cleaner Engine Idler Muffler Engine ProtectionEmissions Fuel System Governor VantageAuxiliary Power Circuit bREAKER Other Circuit bREAKERS ReceptaclesSafety Precautions VRD Voltage Reduction DeviceLocation and Ventilation StackingTowing Vehicle MountingPRE-OPERATION Engine Service OILFuel Engine Cooling SystemRemote Control Electrical ConnectionsMachine Grounding Welding TerminalsAuxiliary Power Receptacles Welding Output CAbLESTotal COMbINED Length of Electrode and Work CAbLES Duplex Receptacles and Gfci ModulesSTANDbY Power Connections Connection of Vantage 300 to Premises Wiring Connection of Lincoln Electric Wire Feeders Connection of LN-15 to the Vantage Shut the welder offAcross The-Arc Model Control Cable ModelInstallation General Description Weld Mode Selector Switch Figure b.1Ground Stud Wire Feeder Voltmeter SwitchTAbLE b.1 Coolant Temperature GAUGE-A indicator Engine ControlsGlow Plug Push bUTTON Electric Fuel GAUGE- The electric fuelWelder Operation Stopping the EngineTypical Vantage 300 Fuel Consumption TIG Welding Typical Current Ranges 1 for Tungsten ELECTRODES2Downhill Pipe Welding TAbLE b.3Wire WELDING-CV Auxiliary PowerARC Gouging TAbLE b.4TIG Options Wire Feeder OptionsPLASMA CUTTING Routine Maintenance Engine Oil ChangeAIR Cleaner OIL Filter ChangeService Instructions Single- and Two-Stage Engine Air CleanersCooling System Tightening the FAN bELTBLEEDING the Fuel System See Deutz engine manualEngine Adjustment Servicing Optional SparkArrestor Fuel FilterWelder / Generator Maintenance Gfci Module Testing and Resetting ProcedureTROUbLESHOOTING PRObLEMS SymptomsPOSSIbLE Cause Recommended Course of ActionWelding without a control cable Contact your local Lincoln Faulty PC board or welder alterna Field Service Facility Your local Lincoln AuthorizedDiagrams Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Dimension Print L12573-1Vantage Precaucion Warnung