Lincoln Electric IM992 manual Electric Shock can kill

Page 3

ii

SAFETY

ii

 

 

ELECTRIC SHOCK can kill.

3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free

gloves to insulate hands.

3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.

In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:

Semiautomatic DC Constant Voltage (Wire) Welder.

DC Manual (Stick) Welder.

AC Welder with Reduced Voltage Control.

3.c. In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically “hot”.

3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.

3.e. Ground the work or metal to be welded to a good electrical (earth) ground.

3.f. Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.

3.g. Never dip the electrode in water for cooling.

3.h. Never simultaneously touch electrically “hot” parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.

3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.

3.j. Also see Items 6.c. and 8.

ARC RAYS can burn.

4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.

4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.

4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.

FUMES AND GASES can be dangerous.

5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases. When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep

fumes and gases away from the breathing zone. When welding with electrodes which require special ventilation such as stainless or hard facing (see instructions on container or MSDS) or on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and within applicable OSHA PEL and ACGIH TLV limits using local exhaust or mechanical ventilation. In confined spaces or in some circum- stances, outdoors, a respirator may be required. Additional precautions are also required when welding on galvanized steel.

5.b. The operation of welding fume control equipment is affected by various factors including proper use and positioning of the equipment, maintenance of the equipment and the spe- cific welding procedure and application involved. Worker exposure level should be checked upon installation and periodically thereafter to be certain it is within applicable OSHA PEL and ACGIH TLV limits.

5.c. Do not weld in locations near chlorinated hydrocarbon vapors coming from degreasing, cleaning or spraying operations. The heat and rays of the arc can react with solvent vapors to form phosgene, a highly toxic gas, and other irritating prod- ucts.

5.d. Shielding gases used for arc welding can displace air and cause injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe.

5.e. Read and understand the manufacturer’s instructions for this equipment and the consumables to be used, including the material safety data sheet (MSDS) and follow your employer’s safety practices. MSDS forms are available from your welding distributor or from the manufacturer.

5.f. Also see item 1.b.

Image 3
Contents Vantage Safety Depends on YouSafety Electric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionPrécautions DE Sûreté IvSAFETYOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTAbLE of Contents Section F ViiSection D Section EVantage Height Width Depth WeightAIR Cleaner Engine Idler Muffler Engine Protection Emissions Fuel System GovernorReceptacles Auxiliary Power Circuit bREAKER Other Circuit bREAKERSStacking Safety PrecautionsVRD Voltage Reduction Device Location and VentilationVehicle Mounting TowingEngine Cooling System PRE-OPERATION Engine ServiceOIL FuelWelding Terminals Remote ControlElectrical Connections Machine GroundingDuplex Receptacles and Gfci Modules Auxiliary Power ReceptaclesWelding Output CAbLES Total COMbINED Length of Electrode and Work CAbLESSTANDbY Power Connections Connection of Vantage 300 to Premises Wiring Control Cable Model Connection of Lincoln Electric Wire FeedersConnection of LN-15 to the Vantage Shut the welder off Across The-Arc ModelInstallation General Description Figure b.1 Weld Mode Selector SwitchWire Feeder Voltmeter Switch Ground StudTAbLE b.1 Electric Fuel GAUGE- The electric fuel Coolant Temperature GAUGE-A indicatorEngine Controls Glow Plug Push bUTTONStopping the Engine Welder OperationTypical Vantage 300 Fuel Consumption TAbLE b.3 TIG WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 Downhill Pipe WeldingTAbLE b.4 Wire WELDING-CVAuxiliary Power ARC GougingWire Feeder Options TIG OptionsPLASMA CUTTING Engine Oil Change Routine MaintenanceOIL Filter Change AIR CleanerSingle- and Two-Stage Engine Air Cleaners Service InstructionsSee Deutz engine manual Cooling SystemTightening the FAN bELT BLEEDING the Fuel SystemFuel Filter Engine AdjustmentServicing Optional Spark ArrestorGfci Module Testing and Resetting Procedure Welder / Generator MaintenanceTROUbLESHOOTING Cause Recommended Course of Action PRObLEMSSymptoms POSSIbLEWelding without a control cable Contact your local Lincoln Faulty PC board or welder alterna Your local Lincoln Authorized Field Service FacilityDiagrams Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams L12573-1 Dimension PrintVantage Precaucion Warnung