Lincoln Electric IM992 manual Weld Mode Selector Switch, Figure b.1

Page 21

b-2

OPERATION

b-2

 

FIGURE b.1

 

1

2

3

4

13

12

17

22

16

20

5

WELDING CONTROLS (Figure b.1)

1.OUTPUT CONTROL- The OUTPUT dial is used to preset the output voltage or current as displayed on the digital meters for the five welding modes. When in the CC-STICK, ARC GOUGING or CV-WIRE modes and when a remote control is connected to the 6-Pin or 14-Pin Connector, the auto-sensing circuit automatically switches the OUTPUT CONTROL from control at the welder to the remote control.

When in the DOWNHILL PIPE mode and when a remote control is connected to the 6-Pin or 14-Pin

connector, the output control is used to set the max- imum current range of the remote.

EXAMPLE: When the OUTPUT CONTROL on the welder is set to 200 amps the current range on the

remote control will be 40-200 amps, rather than the full 40-300 amps. Any current range that is less than the full range provides finer current resolution for more fine tuning of the output.

In the CV-WIRE mode, if the feeder being used has a volt- age control when the wire feeder control cable is connect- ed to the 14-Pin Connector, the auto-sensing circuit auto- matically makes OUTPUT CONTROL inactive and the wire feeder voltage control active. Otherwise, the OUT- PUT CONTROL is used to preset the voltage

11

9

10

14

15

8

7

23

21

18

19

6

When in the TOUCH START TIG mode and when an Amptrol is connected to the 6-Pin Connector, the OUT- PUT dial is used to set the maximum current range of the CURRENT CONTROL of the Amptrol.

2. DIGITAL OUTPUT METERS-The digital meters allow the output voltage (CV-WIRE mode) or current (CC-STICK,DOWN HILL PIPE and TIG modes) to be set prior to welding using the OUTPUT control dial. During welding, the meter display the actual output voltage (VOLTS) and current (AMPS). A memory feature holds the display of both meters on for seven seconds after welding is stopped. This allows the operator to read the actual current and voltage just prior to when welding was ceased.

While the display is being held the left-most decimal point in each display will be flashing. The accuracy of the meters is +/- 3%.

3. WELD MODE SELECTOR SWITCH-

(Provides Five selectable welding modes)

CV-WIRE

ARC GOUGING

DOWNHILL PIPE CC-STICK TOUCH START TIG

VANTAGE® 300

Image 21
Contents Vantage Safety Depends on YouSafety Electric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionPrécautions DE Sûreté IvSAFETYOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTAbLE of Contents Section D ViiSection E Section FAIR Cleaner Engine Idler Muffler Engine Protection Height Width Depth WeightEmissions Fuel System Governor VantageReceptacles Auxiliary Power Circuit bREAKER Other Circuit bREAKERSVRD Voltage Reduction Device Safety PrecautionsLocation and Ventilation StackingVehicle Mounting TowingOIL PRE-OPERATION Engine ServiceFuel Engine Cooling SystemElectrical Connections Remote ControlMachine Grounding Welding TerminalsWelding Output CAbLES Auxiliary Power ReceptaclesTotal COMbINED Length of Electrode and Work CAbLES Duplex Receptacles and Gfci ModulesSTANDbY Power Connections Connection of Vantage 300 to Premises Wiring Connection of LN-15 to the Vantage Shut the welder off Connection of Lincoln Electric Wire Feeders Across The-Arc Model Control Cable ModelInstallation General Description Figure b.1 Weld Mode Selector SwitchWire Feeder Voltmeter Switch Ground StudTAbLE b.1 Engine Controls Coolant Temperature GAUGE-A indicatorGlow Plug Push bUTTON Electric Fuel GAUGE- The electric fuelStopping the Engine Welder OperationTypical Vantage 300 Fuel Consumption Typical Current Ranges 1 for Tungsten ELECTRODES2 TIG WeldingDownhill Pipe Welding TAbLE b.3Auxiliary Power Wire WELDING-CVARC Gouging TAbLE b.4Wire Feeder Options TIG OptionsPLASMA CUTTING Engine Oil Change Routine MaintenanceOIL Filter Change AIR CleanerSingle- and Two-Stage Engine Air Cleaners Service InstructionsTightening the FAN bELT Cooling SystemBLEEDING the Fuel System See Deutz engine manualServicing Optional Spark Engine AdjustmentArrestor Fuel FilterGfci Module Testing and Resetting Procedure Welder / Generator MaintenanceTROUbLESHOOTING Symptoms PRObLEMSPOSSIbLE Cause Recommended Course of ActionWelding without a control cable Contact your local Lincoln Faulty PC board or welder alterna Your local Lincoln Authorized Field Service FacilityDiagrams Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams Diagrams L12573-1 Dimension PrintVantage Precaucion Warnung