Lincoln Electric IM986 manual Single ARM

Page 18

POWER WAVE® i400

Electrode

Connection

AutoDrive 4R90

K2685-2

Wire Feeder

Gas

Air

ARC Mate 1XXiC

* Electrode

Cable (+)

K2163-xx or

K1842-xx

Optional Work

Sense Lead (21)

FANUC Robotics R-30iA "a-cabinet" Controller with Integrated Op Box

ArcLink XT

Ethernet Cable

Power Wave i400

K2669-2

Circuit Breaker (15 Amp)

Devicenet

Connector

Wire Feeder Connector

Voltage Sense

Connector

TYPICAL STAND ALONE SYSTEMS

A-9

INSTALLATION

Wire Feeder Control cable K1785-xx

Work

Piece

* Work

Cable (-)

K2163-xx or

K1842-xx

ArcLink

Connector

ArcLink XT Ethernet Connector

(SINGLE ARM)

OR

* Refer to Output Cable guidelines for recommended cable size in PowerWave i400 Instruction Manual.

A-9

Image 18
Contents Power Wave Safety Depends on YouSafety Mar ʻ95Electric Shock can kill AUGIii JanPrécautions DE Sûreté Mar. ʻ93Electromagnetic Compatibility EMC Safety Thank You ViiTable of Contents Operating Temperature Range Phase InputHeight Width Depth Weight Storage Temperature RangeClass F EnclosureClass K2673-23 155CInstallation Safety PrecautionsInput and Grounding Connections Input Fuse and Supply Wire ConsiderationsPower Supply Connection for the Fanuc R30iA Controller Input ConnectionsConnection Diagrams and System Optional EquipmentPower Wave Utilities Fanuc R30iA Controller Mounting Typical Single ARM Typical Master / Slave System Dual ARM Typical I400Percent Electrode and Work Connections General GuidelinesTable A.1 DutyVoltage Sensing Overview Cable INDUCTANCE, and ITS Effects on WeldingRemote Sense Lead Connections Table A.2If Sense Leads are not Used Work Voltage SensingVoltage Sensing Considerations for Multiple Arc Systems See Figure A.3Power Common Equipment Connections Regarding cable placement, best results will beControl Cable Connections General GuidelinesOther SET-UP Issues Operation Electric Shock can killInput Power Three Phase Direct CurrentProduct Description Recommended Processes and EquipmentCase Front Case Front Control DescriptionPin Leads Function Case BackCase Back Components Description 115V / 15A Duplex ReceptacleInternal Controls POWER-UP SequenceCommon Welding Procedures Internal Controls DescriptionBasic Welding Controls Constant Voltage WeldingPulse Welding Non Synergic CVField Installed AccessoriesFactory Installed Optional EquipmentPeriodic Maintenance MaintenanceRoutine Maintenance Calibration SpecificationCapacitor Discharge Procedure Figure D.1aTroubleshooting HOW to USE Troubleshooting GuideUsing the Status LED to Troubleshoot System Problems Table E.1Error Codes for the Power Wave Error Code #Indication Wire Drive Module Problems Recommended SymptomsCourse of Action Observe Safety Guidelines LEDRecommended Weld and ARC Quality Problems DeviceNet PLC Controlled System Touch Sense command From the DeviceNet tab Power SupplyUnder the Produced Assembly that Passive ModeStrike Wire Feed Speed Bad Weld Starting Wire Feed problemThrough the wire conduit. Verify Ly connected and configured asNeeds to be changed, select Respond quicklyAnalog In Active Selections From the DeviceNet tab ModificationBurnback is present Burnback Time Bad Weld Ending Burnback Disabled From the DeviceNet tabOther than Analog Scans Between Updates That Burnback is present for all Analogs Welding set pointsProblems Possible Recommended Symptoms Diagrams Enhanced DiagamDimension Print Power Wave Aviso DE  Use ventilation or exhaust to Guards off