Lincoln Electric IM986 manual Typical Master / Slave System Dual ARM

Page 19

POWER WAVE® i400

Electrode

 

AutoDrive 4R90

 

 

 

Connection

 

K2685-2

 

 

 

 

 

 

 

FANUC Robotics R-30iA

 

 

 

 

 

"a-cabinet" Controller

 

AutoDrive 4R90

 

 

 

with Integrated Op Box

 

 

 

 

(Slave)

 

K2685-2

 

 

 

 

 

Wire Feeder

 

 

 

 

ArcLink XT

Gas

 

 

 

 

Control Cable

 

 

 

 

 

Air

 

ARC Mate 1XXiC (Slave)

 

 

FANUC Robotics R-30iA

 

 

 

 

 

 

 

 

 

"a-cabinet" Controller

 

 

 

 

 

with Integrated Op Box

 

 

* Electrode

 

 

(Master)

 

 

Power Wave i400

 

 

 

 

Cable (+)

 

Circuit Breaker

 

 

 

K2669-2

 

ARC Mate 1XXiC

Optional Work

 

 

(15 Amp)

(Master)

 

 

 

 

 

Sense Lead (21)

 

 

Devicenet

* Electrode

 

 

 

 

Connector

Cable (+)

 

Work

 

 

 

 

 

Piece

 

 

 

 

Optional Work

 

 

 

 

Sense Lead (21)

 

 

 

 

 

Work

* Work

Power Wave i400

Wire Feeder

 

 

Cable (-)

 

 

Piece

 

K2669-2

Connector

 

 

 

 

 

 

 

 

 

Voltage Sense

 

 

 

Wire Feeder

 

Connector

 

 

 

Control Cable

ArcLink

 

 

 

K1785-XX

ArcLink XT

 

 

 

 

Ethernet cable

Connector

 

 

 

 

(Internal)

ArcLink XT

 

 

 

 

 

Ethernet Connector

* Work

Cable (-)

Wire Feeder

Control Cable

K1785-XX

OR

* Refer to Output Cable Guidelines for recommended cable size in PowerWave i400 Instruction Manual.

TYPICAL MASTER / SLAVE SYSTEM (DUAL ARM)

A-10

INSTALLATION

A-10

Image 19
Contents Safety Depends on You Power WaveMar ʻ95 SafetyAUG Electric Shock can killJan IiiMar. ʻ93 Précautions DE SûretéElectromagnetic Compatibility EMC Safety Vii Thank YouTable of Contents Storage Temperature Range Phase InputHeight Width Depth Weight Operating Temperature RangeK2673-23 155C EnclosureClass Class FSafety Precautions InstallationInput Connections Input Fuse and Supply Wire ConsiderationsPower Supply Connection for the Fanuc R30iA Controller Input and Grounding ConnectionsOptional Equipment Connection Diagrams and SystemPower Wave Utilities Fanuc R30iA Controller Mounting Typical Single ARM Typical Master / Slave System Dual ARM I400 TypicalDuty Electrode and Work Connections General GuidelinesTable A.1 PercentTable A.2 Cable INDUCTANCE, and ITS Effects on WeldingRemote Sense Lead Connections Voltage Sensing OverviewSee Figure A.3 Work Voltage SensingVoltage Sensing Considerations for Multiple Arc Systems If Sense Leads are not UsedPower General Guidelines Regarding cable placement, best results will beControl Cable Connections Common Equipment ConnectionsOther SET-UP Issues Electric Shock can kill OperationDirect Current Input Power Three PhaseRecommended Processes and Equipment Product DescriptionCase Front Control Description Case Front115V / 15A Duplex Receptacle Case BackCase Back Components Description Pin Leads FunctionInternal Controls Description POWER-UP SequenceCommon Welding Procedures Internal ControlsConstant Voltage Welding Basic Welding ControlsNon Synergic CV Pulse WeldingOptional Equipment AccessoriesFactory Installed Field InstalledCalibration Specification MaintenanceRoutine Maintenance Periodic MaintenanceFigure D.1a Capacitor Discharge ProcedureHOW to USE Troubleshooting Guide TroubleshootingTable E.1 Using the Status LED to Troubleshoot System ProblemsError Code # Error Codes for the Power WaveIndication Wire Drive Module Recommended Symptoms ProblemsCourse of Action LED Observe Safety GuidelinesRecommended Weld and ARC Quality Problems DeviceNet PLC Controlled System Passive Mode Power SupplyUnder the Produced Assembly that Touch Sense command From the DeviceNet tabLy connected and configured as Bad Weld Starting Wire Feed problemThrough the wire conduit. Verify Strike Wire Feed SpeedModification Respond quicklyAnalog In Active Selections From the DeviceNet tab Needs to be changed, selectThat Burnback is present for all Analogs Welding set points Bad Weld Ending Burnback Disabled From the DeviceNet tabOther than Analog Scans Between Updates Burnback is present Burnback TimeProblems Possible Recommended Symptoms Enhanced Diagam DiagramsDimension Print Power Wave Aviso DE  Use ventilation or exhaust to Guards off