lotor will not run | Tank pressureexceeds preset | Motor will start automatically when tank pressure drops below |
| pressure switch limit | |
| Motor overload protection has | Let motor cool off, andoverload switch will automatically reset. |
| tripped | This may take several minutes. |
| Fuse Mown or circuit breaker | Replace blown fuse or reset circuit breaker. Do not use fuse |
| tripped | or circuit breakerwith higher rating than that specified for your |
|
| branchcircuit. |
|
| 0 Check for proper fuse; ‘Fusetron” type T is acceptable. |
|
| Check for low voltage and proper extension cord size. |
|
| Disconnectother appliances from circuit. Operate compressor |
|
| on a dedicatedcircuit. |
| Check valve stuck open | Removeand dean or replace. |
Pressure bleedervalve on pressure switch has not unloaded head pressure
Wrong wire gauge in cord or excessiveextension cord length
Loose electrical connections
Possibledefective capacitor
Paint spray on internal motor parts
Possibledefective motor
Bleed line by moving pressure switch lever to OFF position before restarting. If bleeder valve does not open, replace bleedervalve.
Check for proper gauge and extension cord length.
Contact authorized service center.
Have checkedat service center. Do not operate the compressor in the paint spray area.
Have checkedat service center.
16 |