Craftsman 921.16474, 921.16475 owner manual Risk to Hearing, Cfm, Psi

Page 4

kvlv/-r,,1'1II_[-e"]

RISK TO HEARING.

Always

wear hearing protection when using an air compressor.

Failure to do so may result

in

 

hearing

loss.

 

 

 

The power cord on this product contains lead, a chemical known to the State of California to cause

 

cancer, and birth defects or other reproductive harm. Wash hands after handling.

 

NOTE: ELECTRICAL WIRING.

Refer to the air compressor's serial label for the unit'svoltage

and amperage requirements.

Ensure

 

[hat all wiring is done by a licensed electrician, in accordance with the National Electrical code.

Drain the moisture from the tank on a daily basis. A clean, dry tank will help prevent corrosion.

Pull the pressure relief valve ring daily to ensure that the valve is functioning properly, and to clear the valve of any possible obstructions.

To provide proper ventilation for cooling, the compressor must be kept a minimum of 12 inches (31 cm) from the nearest wall, in a vvell-ventilated area.

Fasten the compressor down securely if transporting is necessary. Pressure must be released from the tank before transporting.

Protect the air hose and electric cord from damage and puncture. Inspect them weekly for weak or worn spots, and replace if necessary.

To reduce the risk of electric shock, do not expose to rain. Store indoors.

Never operate the compressor if the power cord or plug are damaged. Have the unit serviced at a Sears or other qualified service center.

CFM

Cubic feet per minute; a unit of measure of air flow.

PSI

Pounds per square inch; a unit of measure of air pressure.

Kick-in pressure

Factory set low pressure point that starts the compressor to repressurize the tank to a higher pressure.

Kick-out pressure

Factory set high pressure point that stops the compressor from increasing the pressure in the tank above a certain level.

Well-ventilated

A means of providing fresh air in exchange for dangerous exhaust or vapors.

Dedicated circuit

An electrical circuit reserved for the exclusive use of the air compressor.

4

200-2792

Image 4
Contents AIR Compressor Craftsman ONE Year Full Warranty MaintenanceOperating Instructions Running TankRisk of Fire or Explosion Risk of Bursting Risk of Electrical ShockRisk of Injury Risk of BurnsCFM Risk to HearingPSI Basic AIR Compressor Assembling the CompressorComponents Motor Reset Switch Extension Cords Electrical WiringGrounding Instructions Propel debris that may cause eye injury. Wear safety Goggles when Opening petcockDaily START-UP ShutdownMaintenance Adjusting Drive Belt TensionDraining the Tank Checking the OILReplacing or Cleaning the Check Valve Pulley AlignmentRisk INJURY. This unit startsCleaning the AIR Filter Testing for LeaksChecking the Relief Valve StorageProblem Possible Cause Solution Vertical tank 27 Gal El tanque vertical R6servoir vertical Asme13F 200-2792 Article No / P Qty Articulo Num / PDescription Descripcion Io.I Available Service Kits Cuadro DE Deteccion DE Fallos Intervalos DE ServicioEsquema DE LA Piezas Lista DE LAS Piezas Riesgo DE Explosion Riesgo AL Sentido DEL OiDO Nota Cableado ElectricoBar Presion de conexionComponentesbasicos DEL Compresor DE Aire MontajeInterruptor DE Restablecimiento DEL Motor Cordones Prolongadores Cableado EL#CTRICOInstrucciones DE CONEXlON a Tierra Para Modelos Conectados CON CordonArranque Diario ParadaAbierto Mantenimiento Desagoe DEL TanqueCambio DE Aceite Tension DE LA Correa Y Alineacion DE LA PoleaLlLEsta Alineacion DE LA PoleaSubstituyendo O Limpiando LA Valvula DE Cheque Limpieza DEL Filtro DE Aire Deteccion DE FugasAlmacenamiento Revision DE LA Valvula DE AlivioCausa Posible ProblemaSolucion Pression Pression DE Artisan UNE Pleine Garantie DAN PendantMODleLE Sections Risque Auditif Remarque Cablage IlectiquePression douverture Pression darret=LleMENTSDE Base DU Compresseur Dair Assemblage DU CompresseurInterrupteur DE Remise EN Marche DU Moteur Cablage Ilectique RallongesInstructions DE Mise .&.LA Terre Pour Modiles .& CordonMise EN Marche Quotidienne ARR#TOFF C Auto Ouvert FERN# EEntretien Vidange DU ReservoirTension DE LA Courroie ET Aligneimient DE LA Poulie Riglage DE LA Tension DE LAAlignement DE LA Poulie Remplaant OU Nettoyant LE Clapet Anti RetourEssai Ditanchiiti EntreposageProbleme Cause Possible Solution Your Home Wsear&com