ELECTRICAL WIRING

Refer to the air compressor's serial label for the unit's voltage and amperage requirements.

Use a dedicated circuit

For best performance and reliable starting, the air compressor must be plugged into a dedicated circuit, as close as possible to the fuse box or circuit breaker. The compressor will use the full capacity of a typical 15 amp household circuit. If any other electrical devices are drawing from the compressor's circuit, the compressor may fail to start. Low voltage or an overloaded circuit can result in sluggish starting that causes the motor overload protection system or circuit breaker to trip, especially in cold conditions.

NOTE: To handle the initial electrical toad of starting the air compressor, a circuit breaker is recommended. If the air compressor is connected to a circuit protected by a fuse, use dual element time delay fuses (Buss Fusetron type "T" only).

EXTENSION CORDS

NOTE: Avoid use of extension cords.

For optimum performance, plug the compressor power cord directly into a grounded walt socket. Do not use an extension cord unless absolutely necessary. Instead, use a longer air hose to reach the area where the air is needed.

If use of an extension cord cannot be avoided, the cord should be no longer than 50 feet and be a minimum wire size of 12 gauge (AWG). Do not use a 16 or 14 gauge extension cord.

Use only a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that wilt accept the plug on the product. Make sure your extension cord is in good condition. An undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. The smaller the gauge number, the heavier the cord.

GROUNDING INSTRUCTIONS

FOR CORD-CONNECTED MODELS:

This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current.

This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinance.

IL_Improper installation of the grounding plug can result in a risk of electric shock. If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either fiat blade terminal of the plug. The wire" insulation having an outer surface that is green with or without yellow stripes is the grounding wire.

This product is for use on a 115 or 230 volt circuit. A cord with a grounding plug, as shown here, shall be used.

Make sure that the product is connected to an outlet having the same configuration as the plug (see Fig. 5). No adapter should be used with this product.

Check with a licensed electrician if the grounding instructions are not completely understood, or if in doubt as to whether the

200-2792

product is properly grounded. Do not modify the plug provided; if it will not fit the outlet, have the proper outlet installed by a licensed electrician.

Fig. 5

""- Grounded Outlet

Box

_ Grounded Outlet

115V230V

115VOLT

15AMP

Plug,,...

Grounding Pin

Image 7
Contents AIR Compressor Running Tank Craftsman ONE Year Full WarrantyMaintenance Operating InstructionsRisk of Burns Risk of Fire or Explosion Risk of BurstingRisk of Electrical Shock Risk of InjuryCFM Risk to HearingPSI Basic AIR Compressor Assembling the CompressorComponents Motor Reset Switch Extension Cords Electrical WiringGrounding Instructions Shutdown Propel debris that may cause eye injury. Wear safetyGoggles when Opening petcock Daily START-UPChecking the OIL MaintenanceAdjusting Drive Belt Tension Draining the TankINJURY. This unit starts Replacing or Cleaning the Check ValvePulley Alignment RiskStorage Cleaning the AIR FilterTesting for Leaks Checking the Relief ValveProblem Possible Cause Solution Asme Vertical tank 27 Gal El tanque vertical R6servoir vertical13F 200-2792 Article No / P Qty Articulo Num / PDescription Descripcion Io.I Available Service Kits Cuadro DE Deteccion DE Fallos Intervalos DE ServicioEsquema DE LA Piezas Lista DE LAS Piezas Riesgo DE Explosion Presion de conexion Riesgo AL Sentido DEL OiDONota Cableado Electrico BarMontaje Componentesbasicos DEL Compresor DE AireInterruptor DE Restablecimiento DEL Motor Para Modelos Conectados CON Cordon Cordones ProlongadoresCableado EL#CTRICO Instrucciones DE CONEXlON a TierraArranque Diario ParadaAbierto Tension DE LA Correa Y Alineacion DE LA Polea MantenimientoDesagoe DEL Tanque Cambio DE AceiteLlLEsta Alineacion DE LA PoleaSubstituyendo O Limpiando LA Valvula DE Cheque Revision DE LA Valvula DE Alivio Limpieza DEL Filtro DE AireDeteccion DE Fugas AlmacenamientoCausa Posible ProblemaSolucion Pression Pression DE Artisan UNE Pleine Garantie DAN PendantMODleLE Sections Pression darret Risque Auditif Remarque CablageIlectique Pression douvertureAssemblage DU Compresseur =LleMENTSDE Base DU Compresseur DairInterrupteur DE Remise EN Marche DU Moteur Pour Modiles .& Cordon Cablage IlectiqueRallonges Instructions DE Mise .&.LA TerreOuvert FERN# E Mise EN Marche QuotidienneARR#T OFF C AutoRiglage DE LA Tension DE LA EntretienVidange DU Reservoir Tension DE LA Courroie ET Aligneimient DE LA PoulieAlignement DE LA Poulie Entreposage Remplaant OU Nettoyant LE Clapet AntiRetour Essai DitanchiitiProbleme Cause Possible Solution Wsear&com Your Home