Pressure Switch (see A)
This switch turns on the compressor. It is operated manually, but when in the ON position, it allows the compressor to start up or shut down automatically, without warning, upon air demand.
ALWAYS set this switch to OFF when the compressor is not being used, and before unplugging the compressor.
Pressure Relief Valve (see B)
If the pressure switch does not shut down the motor when pressure reaches the preset level, this valve wilt pop open automatically to prevent over pressurization. To operate manually, pull the ring on the valve to relieve air pressure in the tank.
Tank Pressure Gauge (see C)
This gauge measures the pressure level of the air stored in the tank. It is not adjustable by the operator, and does not indicate line pressure.
Air Pressure Regulator (see D)
This air pressure regulator enables you to adjust line pressure to the tool you are using.
__Never exceed the maximum working
pressure of the tool.
Turn the knob clockwise to increase pressure, and counterclockwise to decrease pressure.
Regulated Pressure Gauge (see E)
This gauge measures the regulated line pressure.
Quick Connect (see F)
A quick release for attaching and removing the air hose.
MOTOR RESET SWITCH
__Ensurethat all guards and shrouds are in
place before pressing the reset switch to restart the motor.
If the motor shuts down because of overload, wait
NOTE: Some models are equipped with a dual voltage | G |
motor 115/230 volt. Most models are factory wired |
|
for 115 volt operation. If conversion from 115 volt |
|
to 230 volt is required, refer to the motor |
|
nameplate and have the conversion performed by |
|
a Licensed Electrician. |
|
B
Horizontal tank
A
B
Vertical tank
Fig. 3
Fig. 4
6 |