Xantrex Technology TC2 204060 manual Three-Stage Charging

Page 41

TC2 204060 Series BattChg Owners Guide.book Page 29 Friday, July 8, 2011 11:44 AM

Installing Batteries

Three-Stage Charging

The three-stage charging mode employs the following sequence: Bulk, Absorption, and Float. During the Bulk stage the batteries are accepting a constant maximum current. In the Absorption stage, the battery voltage is held constant and the current declines. A battery will “gas” (produce hydrogen and oxygen) when its voltage exceeds the “gassing” voltage. Finally, in the Float stage, the charger continues to provide voltage at a lower level to maintain the battery in a fully charged state. If there is no load on the battery, it will typically draw very little current. The charger, however, is able to provide current to its full rating to power auxiliary DC loads on the battery.

The charger will restart the charging cycle in the Bulk stage if the lowest battery voltage of the three banks drops below 12.5 V (12 Vdc chargers) or 25 V (24 Vdc chargers) for 15 minutes. After seven days, the charger will automatically restart charging in order to refresh the batteries.

Vbat = Vabs

lout < 10% lrating

for 1 minute

for 1 minute

Battery Voltage

 

Vbat = Vgas

Vbat < 12.5 V

for 1 minute

for 15 minutes

Vgas voltage

 

 

 

Charge

 

 

 

start

 

 

 

BULK

ABS

ABS

FLOAT

CC

CV

 

 

ABS CV timeout

Time

 

 

 

max 5 hrs

Start of

 

 

 

FLOAT timeout

 

 

 

max 7 days

charging cycle

 

 

 

Total ABS timeout

 

 

max 8 hrs

Figure 9 Three-Stage Charging Process

 

 

975-0526-01-02

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 41
Contents Series Battery Charger Page Product Numbers TrademarksExclusion for Documentation Date and RevisionStatement of Hazard About This GuideRelated Information Electrical Shock Hazard Important Safety InstructionsPersonal Injury Hazard Fire and Burn HazardExplosion Hazard Precautions When Working With Batteries Exposure to Chemicals and Gases Hazard Precautions When Placing the Battery ChargerRisk of Damage to the Battery Charger Viii FCC Information to the UserContents Page Introduction Truecharge2 Battery ChargerStandard and Protection Features Introduction Front Panel Truecharge 2 Battery Charger FeaturesAC wiring compartment Truecharge2 Series Battery Charger Owner’s GuideRear Panel DescriptionItem Description Onboard Control and Status Display PanelTruecharge2 Series Battery Charger Owner’s Guide Risk of Battery Damage Improper Installation by AN Unqualified Installer Preparing For InstallationYou need the following materials Tools and MaterialsExplosion Hazard for IEC Models only LocationCondition Requirement Mounting Orientations Deck and Horizontal Electrical Shock and Fire Hazard Wiring RequirementsWire Length Wire Size AWG and mm2 DC WiringInjury Fire HazardAWG Other examples of AC wiring requirements Battery Bank Size RequirementsInstallation Sequence Installing the Truecharge 2 Battery ChargerMounting the Battery Charger To mount the Truecharge2 Battery ChargerTo connect the DC chassis ground earth Connecting the DC Chassis Ground EarthShock Hazard Installing DC WiringAccidental Short or Spark Hazard Reverse Polarity Damage For one battery or bankFor more than one battery or bank Installing the Truecharge 2 Battery Charger AC wiring access hole Installing AC WiringTapered end of strain relief AC supply wiring Conductor Charger Pigtail AC Supply Wire Color CodeScrew to secure the wiring compartment cover Explosion AND/OR Fire Hazard Powering UpDamage to the Battery Charger Installing a Parallel ConfigurationFault and Warning Conditions Powering up after installing a parallel configurationWhen Configuring the Battery Chargers When Equalizing BatteriesInput Voltage Operating and Derating Installing BatteriesAC source Multi-Stage ChargingThree-Stage Charging Two-Stage Charging Temperature Considerations Battery QualificationTo force a battery detection sequence Charging Voltage SetpointsSetting the Battery Temperature without a BTS Operating DC Loads Configuring the Battery Bank Type Configuring the Truecharge2 Battery ChargerConfiguring the Charger Mode To charge your batteries Mode Charger Status LED-ONCharging Batteries Charging Batteries Equalizing Flooded Batteries Risk of Equipment Damage Performing An EqualizationEXPLOSION, FIRE, and Burn Hazards To equalize your batteriesEqualizing Flooded Batteries Transitioning the Charger to ON, Standby, or Disabled Reporting While Charging or Equalizing Accessing Charger InformationReading Onboard Display LEDs Standby Reporting Without AC Power or While onFault or Warning Solution Condition Fuse on Using a Generator As Source Power Maintaining the Charger Replacing the DC Output Fuse Improper Installation by AN Unqualified InstallerModel Fuse Replacement RatingsPossible Cause Solution TroubleshootingTroubleshooting Disconnect all loads or switch loads off 975-0526-01-02 Troubleshooting Physical Specifications AC Input Specifications SpecificationsDC Output Specifications Environmental Specifications Regulatory Approvals Protection FeaturesWarranty Warranty and Return InformationWarranty and Return Information Product DisclaimerOut of Warranty Service Return Material Authorization PolicyReturn Procedure Information About Your System Page Xantrex Technology USA Inc