2-3 Standard Features
Mechanical Features
Vent Valve. The vent valve extends vacuum pump life by allowing the pump to run unloaded (not drawing a vacuum on a station) for a specified period of time before it shuts off. The alternative, without the vent valve would be to constantly turn the pump on and off whenever a convey cycle is initiated.
Common Purge Valve Output Control for Each Pump. This feature allows any remaining material to be cleaned out of the material lines.
Blowback Filter Cleaning. When this feature is enabled, the controller periodically sends compressed air backward through the pump’s air filter to dislodge accumulated dust and debris.
Electrical Features
•115/1/60 supply voltage
•24 VDC control voltage
•
•
•Branch circuit fusing
Controller Features
•Mitsubishi programmable control with LED display and keypad interface
•Monitors Station status and Pump status
1 | Chapter 2: Functional Description | 12 of 38 |