TRANSPORT
Push the knob of the pressure switch to “OFF” and disconnect it from the power source before move the compressor. Transport the compressor in the correct manner.
OPERATION
1.
Insert the plug into the receptacle and start the compressor by pulling the knob of the pressure switch to “ON” (Refer to Fig. 2).
WARNING: Do not stop or start the compressor by use of the plug. Always use “ON/OFF”
knob located on the pressure switch.
The operation of the compressor is automatic and is controlled by the pressure switch which stops it when the pressure in the
The motor of the compressor is fitted with a thermal protection with manual reset
CAUTION: Wear appropriate personal hearing protection during use. Under some
conditions and duration of use, noise from
English
3.Shutdown
(1)Push the knob of the pressure switch to “OFF” (Refer to Fig. 1 and Fig. 2).
(2)Unplug the plug from power source.
(3)Open the drain cock located at the lower part of the tank (Fig. 7).
Drain cock
Tank
Fig.7
WARNING: Risk of bursting. When the tank gets cor- roded, there is a risk of breakdown. Water
will condense in the air tank. If not drai- ned, water will corrode and weaken the air tank causing a risk of air tank rupture. Drain tank daily or after 4 hours of use. The drain contains moisture in the air, abra- sion particles, rust, etc.. To drain tank open valve slowly and tilt compressor to empty accumulated water. Keep face and eyes away from drain cock.
4.About the thermal protector
The thermal protector operates to stop the motor when a problem such as a motor overload, etc.. occurs. If the motor should stop during operation, proceed as follows.
this product may contribute to hearing loss.
2.Adjustment of working pressure
Unlock the knob of the pressure reducer pulling it up, adjust the pressure to the required level by turning the knob clockwise to increase and counterclockwise to decrease.
A pressure gauge (B) is provided to know when the required pressure is reached, lock the knob by pushing it down firmly (Refer to Fig. 6).
When adjusting the pressure, check and make sure that a pressure gauge for the tank has the pressure level that is higher than that of the pressure to be adjusted.
It is also imperative that you make adjustment by slowly starting up the pressure from the level that is lower than the pressure to be adjusted.
WARNING: Check the manufacturer’s maximum pressure rating for nailers, staplers and
accessories. Compressor outlet pressure must be regulated so as to never exceed the maximum pressure rating of the nailers, staplers and accessories.
(1)Push the pressure switch knob to the “OFF” position and disconnect the plug from the receptacle (Fig. 2).
(2)If the extension cord does not conform to the specifications given on page 6 replace with an extension cord such as that shown on page 6. If the capacity of the power supply is insufficient, increase the power supply capacity to remove the cause of a flow of excessive current
(3)Wait approximately 5 minutes, then press the reset switch of the thermal protector (Fig. 8).
(4)Start up. If the motor still stops during operation, please contact the service center.
Switch of thermal protector
Knob of the pressure | Quick coupler | Fig.8 |
reducer | (air outlet) |
|
|
|
MAINTENANCE
Pressure gauge |
| Pressure gauge (A) |
(B) indicates the |
| indicates the pressure |
working pressure | Fig.6 | in the air tank |
|
|
WARNING: Disconnect the compressor from the power source and remove the compressed
air from the air tank before performing the maintenance operations. Allow the compressor to cool before performing the maintenance operations.
- 9 -