DeWalt D55167 Extension Cords, Voltage and Circuit Protection, Compatibility Location, Electrical

Page 11

Extension Cords

If an extension cord must be used, be sure it is:

a 3-wire extension cord that has a 3-blade grounding plug, and a 3slot receptacle that will accept the plug on the product

in good condition

no longer than 50 feet (15.2 m)

12 gauge (AWG) or larger. (Wire size increases as gauge number decreases. 10 AWG and 8 AWG may also be used. DO NOT USE 14 OR 16 AWG.)

NOTICE: The use of an undersized extension cord will cause voltage to drop resulting in power loss to the motor and overheating. Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as needed. Always use a minimum 3/8" (9.5 mm) or greater air hose rated at 300 psi.

Voltage and Circuit Protection

Refer to the Voltage and Minimum Branch Circuit Requirements under Pump/Motor Specifications.

CAUTION: Certain air compressors can be operated on a 15 amp circuit if the following conditions are met.

Voltage supply to circuit must comply with the National

Electrical Code.

Circuit is not used to supply any other electrical needs.

Extension cords comply with specifications.

Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse. NOTE: If compressor is connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses should be marked “D” in Canada and “T” in the US.

If any of the above conditions cannot be met, or if operation of the compressor repeatedly causes interruption of the power, it may be

necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.

Compatibility

NOTE: Always use an air line filter to remove moisture and oil vapor when spraying paint.

Location

Place the air compressor in a clean, dry and well ventilated area at least 12" (30.5 cm) away from the wall or other obstructions that will interfere with the flow of air. Keep the compressor away from areas that have dirt and/or volatile fumes in the atmosphere. These impurities may clog the intake filter and valves, causing inefficient operation.

Warning: The air compressor pump and shroud are designed to allow for proper cooling.The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.

Place the air compressor on a flat surface resting on the rubber feet and wheels.

Electrical

Refer to all safety instructions before using unit. Observe extension cord safety instructions if necessary. Always move the Auto/Off switch (A) to the OFF position before removing the plug from the outlet.

Transporting

When transporting the compressor in a vehicle, trailer, etc., make sure the tank is drained and the unit is secured with straps to prevent tipping. Use care when driving to prevent tipping the unit over in the vehicle. Damage can occur to the compressor or surrounding items if the compressor is tipped.

English

11

Image 11
Contents D55167 Declared Noise Emission Values per ISO Pump/Motor SpecificationsSpecifications D55167 Air CompressorSave these instruction Definitions Safety GuidelinesImportant Safety Instructions What can happen How to prevent itCompressor ventilation With the product when it isUnit when not in use Restricting anyAttachments & accessories Instructions under TIresElectrical Grounding See GroundingCause serious injury if they By a DeWALT factory serviceService center Moving parts such asUse additional air hose to reach high locations Never defeat the safety fea­Air compressor Compressor at all timesFeatures Fig AIR Intake Filter AssemblyGrounding Instructions Electrical Extension CordsVoltage and Circuit Protection Compatibility LocationShut-down Fig Preparation For Use Pre-Start Checklist FigOperating Procedures Start-up Fig Procedure Daily Weekly See tank MaintenanceMaintenance Chart Checking Safety ValveRepairs Accessories Service InformationDraining Air Tank Fig Checking Air Filter Element FigGlossary Full One Year WarrantyPossible Solution Troubleshooting GuideTroubleshooting Codes Problem CodeExplode Compressor on its own branch circuit Check for proper fuse. You should use a time delay fuseArea. See Risk of Explosion or Fire warning under Important Fuse blown, circuit breaker trippedFiche technique Compresseur d’air, modèle D55167Fiche technique de la pompe/du moteur Après toute manipulation Définitions Lignes directrices en Matière de sécuritéConserver ces directives Directives de sécurité importantesMatériaux inflammables Vapeurs inflammablesExplosion Si vous aspergez desAvertissement risque d’Éclatement Pneus Accessoires Ce qui peut se produire Avertissement risque provenant des Objets projetÉs en l’air Avertissement risque de choc ÉlectriqueAvertissement attention surfaces chaudes Avertissement risque associÉ Aux piÈces mobilesCE QUI Peut SE Produire Avertissement risque associÉ À Utilisation dangereuseCaractÉristiques FIG Filtre D’ADMISSION D’AIR AssemblageÉlectricien qualifié Directives relatives à la mise à la terreRallonges Protection de la tension et du circuitCompatibilité EmplacementArrêt Fig Mode d’emploiListe de vérification de pré-démarrage Fig Procédures de fonctionnement Démarrage FigProcédure Quoti Hebdo Se reporter EntretienProgramme d’entretien Vérification des éléments du filtre d’air Fig Vérification de la soupape de sûretéVidange du réservoir d’air Fig Garantie complète d’un 1 an AccessoiresInformation sur les réparations RéparationsGlossaire Remplacement Gratuit DES ÉtiquettesProblème Code Solution ProbableGuide de dépannage Codes de dépannageOu d’exploser De l’accessoireLire l’avertissement concernant les risque d’explosion ou Consulter la rubrique Surcharge du moteur sousFrançais Valores de emisión de ruido declarados según ISO Compresor de aire D55167Especificaciones de la Bomba y el Motor EspecificacionesPeligro Riesgo de explosión o incendio Definiciones Normas de seguridadGuarde estas instrucciones Instrucciones de seguridad importantesPeligro Riesgo Respiratorio asfixia ¿Qué puede suceder? Advertencia Riesgo de explosiónNeumáticos Elementos y accesoriosAdvertencia riesgo de descarga eléctrica Advertencia Riesgo DE superficies calientes Advertencia Riesgo de objetos despedidosAdvertencia Riesgo de operación insegura Advertencia riesgo por piezas móviles¿Qué puede suceder? Cómo evitarlo Interruptor de presión Características FIGAtención riesgo por ruidos Interruptor de Auto/apagadoFiltro DE Entrada DE Aire Desconexión de las mangueras Instrucciones de conexión a tierraEnsamblaje Instalación de las manguerasLugar Cables prolongadoresVoltaje y protección del circuito CompatibilidadAdvertencia Riesgo Preparación para el usoLista de control previa a la puesta en marcha Fig Mantenimiento Procedimientos operativos Puesta en marcha FigApagado Fig Drenar el tanque de aire Fig Tabla de mantenimientoControlar la válvula de seguridad Sello o firma del Distribuidor Controlar el elemento del filtro de aire FigAccesorios Póliza de GarantíaExcepciones Garantía completa de un añoCULIACAN, SIN Glosario Solución Posible Guía de detección de problemasCódigos de detección de problemas Válvula aún pierde, debe ser reemplazada Sellos de pérdidasCentro de servicio autorizado DeWALT Válvula de seguridad defectuosaPosible motor defectuosos La presión del tanque excede la presión deSección Mantenimiento Page Page EWALT Industrial Tool Co., 701 Joppa Road, Baltimore, MD