DeWalt D55167 instruction manual Draining Air Tank Fig, Checking Air Filter Element Fig, Repairs

Page 14

English

Draining Air Tank (Fig. 1)

Warning: Risk of unsafe operation. Risk from noise. Air tanks contain high pressure air. Keep face and other body parts away from outlet of drain. Use eye protection [ANSI Z87.1 (CAN/CSA Z94.3)] when draining as debris can be kicked up into face.

Warning: Risk from noise. Use ear protection [ANSI S12.6 (S3.19)] as air flow noise is loud when draining.

NOTE: All compressed air systems generate condensate that

3.Remove filter cover (J) from base.

4.Remove element from filter base.

5.Place new element back in filter base. Purchase replacement parts from your local dealer or authorized service center. Always use identical replacement parts.

6.Snap filter cover to filter base.

j

accumulates in any drain point (e.g. tanks, filter, aftercoolers, dryers). This condensate contains lubricating oil and/or substances which may be regulated and must be disposed of in accordance with local, state, and federal laws and regulations.

1.Ensure Auto/Off switch is in the OFF position.

2.Place a suitable container under the drain valve (H) to catch discharge.

3.Grasp lever on drain valve.

4.Slowly rotate lever to gradually bleed air from air tank.

Warning: Risk of bursting. Drain air tank daily. Water will condense in air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

NOTICE: Risk of property damage. Drain water from air tank may contain oil and rust, which can cause stains.

5.When air tank pressure gauge reads 10 psi, rotate valve to the fully open position.

6.Close drain valve when finished.

Checking Air Filter Element (Fig. 1)

Warning: Hot surfaces. Risk of burn. Outlet tube, pump head, and surrounding parts are very hot, do not touch. Allow compressor to cool prior to servicing.

1.Ensure Auto/Off switch (A) is in the OFF Position.

2.Allow unit to cool.

NOTICE: Risk of unsafe operation. Do not operate without air inlet filter

Accessories

Recommended accessories for use with your tool are available for purchase from your local dealer or authorized service center. If you need assistance in locating any accessory for your tool, please contact DeWALT Industrial Tool Co., 701 East Joppa Road, Baltimore, MD 21286, call 1-800-4-DeWALT (1-800-433-9258) or visit our website www.dewalt.com.

warning: The use of any other accessory not recommended for use with this tool could be hazardous. Use only accessories rated equal to or higher than the rating of the air compressor.

Service Information

Please have the following information available for all service calls: Model Number ____________ Serial Number _________________

Date and Place of Purchase ______________________________

Repairs

To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment should be performed by a DeWALT factory service center, a DeWALT authorized service center or other qualified service personnel. Always use identical replacement parts.

14

Image 14
Contents D55167 D55167 Air Compressor Pump/Motor SpecificationsSpecifications Declared Noise Emission Values per ISOWhat can happen How to prevent it Definitions Safety GuidelinesImportant Safety Instructions Save these instructionRestricting any With the product when it isUnit when not in use Compressor ventilationAttachments & accessories See Grounding TIresElectrical Grounding Instructions underMoving parts such as By a DeWALT factory serviceService center Cause serious injury if theyCompressor at all times Never defeat the safety fea­Air compressor Use additional air hose to reach high locationsFeatures Fig AIR Intake Filter AssemblyGrounding Instructions Compatibility Location Extension CordsVoltage and Circuit Protection ElectricalShut-down Fig Preparation For Use Pre-Start Checklist FigOperating Procedures Start-up Fig Checking Safety Valve MaintenanceMaintenance Chart Procedure Daily Weekly See tankChecking Air Filter Element Fig Accessories Service InformationDraining Air Tank Fig RepairsFull One Year Warranty GlossaryProblem Code Troubleshooting GuideTroubleshooting Codes Possible SolutionExplode Fuse blown, circuit breaker tripped Check for proper fuse. You should use a time delay fuseArea. See Risk of Explosion or Fire warning under Important Compressor on its own branch circuitFiche technique Compresseur d’air, modèle D55167Fiche technique de la pompe/du moteur Directives de sécurité importantes Définitions Lignes directrices en Matière de sécuritéConserver ces directives Après toute manipulationSi vous aspergez des Vapeurs inflammablesExplosion Matériaux inflammablesAvertissement risque d’Éclatement Pneus Accessoires Ce qui peut se produire Avertissement risque de choc Électrique Avertissement risque provenant des Objets projetÉs en l’airAvertissement risque associÉ Aux piÈces mobiles Avertissement attention surfaces chaudesAvertissement risque associÉ À Utilisation dangereuse CE QUI Peut SE ProduireCaractÉristiques FIG Assemblage Filtre D’ADMISSION D’AIRProtection de la tension et du circuit Directives relatives à la mise à la terreRallonges Électricien qualifiéEmplacement CompatibilitéProcédures de fonctionnement Démarrage Fig Mode d’emploiListe de vérification de pré-démarrage Fig Arrêt FigProcédure Quoti Hebdo Se reporter EntretienProgramme d’entretien Vérification des éléments du filtre d’air Fig Vérification de la soupape de sûretéVidange du réservoir d’air Fig Réparations AccessoiresInformation sur les réparations Garantie complète d’un 1 anRemplacement Gratuit DES Étiquettes GlossaireCodes de dépannage Solution ProbableGuide de dépannage Problème CodeDe l’accessoire Ou d’exploserConsulter la rubrique Surcharge du moteur sous Lire l’avertissement concernant les risque d’explosion ouFrançais Especificaciones Compresor de aire D55167Especificaciones de la Bomba y el Motor Valores de emisión de ruido declarados según ISOInstrucciones de seguridad importantes Definiciones Normas de seguridadGuarde estas instrucciones Peligro Riesgo de explosión o incendioPeligro Riesgo Respiratorio asfixia Advertencia Riesgo de explosión ¿Qué puede suceder?Neumáticos Elementos y accesoriosAdvertencia riesgo de descarga eléctrica Advertencia Riesgo de objetos despedidos Advertencia Riesgo DE superficies calientesAdvertencia riesgo por piezas móviles Advertencia Riesgo de operación inseguraInterruptor de Auto/apagado Características FIGAtención riesgo por ruidos ¿Qué puede suceder? Cómo evitarlo Interruptor de presiónFiltro DE Entrada DE Aire Instalación de las mangueras Instrucciones de conexión a tierraEnsamblaje Desconexión de las manguerasCompatibilidad Cables prolongadoresVoltaje y protección del circuito LugarAdvertencia Riesgo Preparación para el usoLista de control previa a la puesta en marcha Fig Mantenimiento Procedimientos operativos Puesta en marcha FigApagado Fig Drenar el tanque de aire Fig Tabla de mantenimientoControlar la válvula de seguridad Póliza de Garantía Controlar el elemento del filtro de aire FigAccesorios Sello o firma del DistribuidorGarantía completa de un año ExcepcionesCULIACAN, SIN Glosario Solución Posible Guía de detección de problemasCódigos de detección de problemas Válvula de seguridad defectuosa Sellos de pérdidasCentro de servicio autorizado DeWALT Válvula aún pierde, debe ser reemplazadaLa presión del tanque excede la presión de Posible motor defectuososSección Mantenimiento Page Page EWALT Industrial Tool Co., 701 Joppa Road, Baltimore, MD