Bryant 581B036--072, 581C024--060 Typical Perfect Humidity t Adaptive Dehumidification System

Page 17

 

LEGEND

 

 

 

 

CB

Circuit Breaker

Terminal (Unmarked)

 

 

 

CR

Cooling Relay

 

 

 

 

 

 

 

DHR

Dehumidify Relay

Splice

 

 

 

DSV

Discharge Solenoid Valve

Factory Wiring

 

 

 

HR

Heater Relay

 

 

 

LPS

Low Pressure Switch

Field Control Wiring

 

 

 

LSV

Liquid Solenoid Valve

 

 

 

LTLO

Low Temperature Lockout

Field Power Wiring

 

 

 

 

Field Splice

 

 

 

 

 

 

 

 

 

Fig. 17 ---Typical Perfect Humidityt Adaptive Dehumidification System

C06128

 

 

 

Humidistat Wiring (208/230-V Unit Shown)

 

 

 

LCT

 

ROOF TOP UNIT

 

 

 

R

 

R

 

 

 

C

 

C

 

 

 

Y1

 

Y1

 

 

 

Y2

 

Y2

 

 

 

G

 

G

 

 

 

W1

 

W1

 

 

 

W2

 

W2

CB

 

 

DEHUM

R1

 

 

 

OC

 

PINK

3.2 AMPS

RED

 

TSTAT WIRES

 

24 V

 

 

 

 

 

 

 

R1

PINK

LTLO

PINK FROM

 

LEGEND

 

 

 

 

 

 

PERFECT HUMIDITY SYSTEM

CB — Circuit Breaker

 

 

 

 

 

 

LLSV

LCT — Light Commercial Thermidistat™ Device

LLSV — Liquid Line Solenoid Valve

LTLO — Low Temperature Lockout

PERFECT HUMIDITY SYSTEM

C06360

Fig. 18 ---Typical Rooftop Unit with Perfect Humidity

Adaptive Dehumidification System with Thermidistat Device

OUTDOOR

AIR OPENING

PANEL

3 SCREWS (SIDE)

C06130

Fig. 19 ---Damper Panel with Manual Outdoor-Air

Damper Installed

C06013

Fig. 20 ---Outdoor-Air Hood Details

17

581B,C

Image 17
Contents Installation Instructions Provide Unit Support Install External Trap for Condensate DrainField Fabricate Ductwork Rig and Place UnitRoof Curb Details Install Gas Piping Install Flue HoodRoof Curb Alignment 581B 036-072 Base Unit Dimensions 581C 024-060 Base Unit Dimensions Field Control Wiring Field Power SupplyHeat Anticipator Settings Make Electrical ConnectionsBase Unit 581B Physical Data 581BUnit Size 581B Base Unit 581C Physical Data 581CUnit Size 581C Power Wiring Connections 581C024---060 Electrical Data 581CElectrical Data 581B Assembly Adjust Factory-Installed OptionsPerfect Humidity Adaptive Dehumidification System Manual Outdoor DamperTypical Perfect Humidity t Adaptive Dehumidification System Outdoor-Air Damper With Hood Attached Supply Air Sensor Temperature Resistance Values Supply Air Temperature SAT SensorTemperature F Outdoor Air Lockout SensorOutdoor Dry Bulb Changeover Economi$er IV Control ModesEconomi$er IV Sensor Usage Differential Dry Bulb ControlEconoMi$er IV Wiring Minimum Position Control Exhaust Set Point AdjustmentDemand Controlled Ventilation DCV Damper MovementThermostats Enthalpy Changeover Set Points Belt Drive Motors Dehumidification of Fresh Air with DCV ControlBelt Drive Motor Mounting CO2Sensor Standard SettingsAccessory Static Pressure 581B Fan Rpm at Motor Pulley Setting With High-Static MotorEvaporator-Fan Motor Data Standard Motor Evaporator-Fan Motor Data High-Static Motors581C Outdoor Sound Power Total Unit 581B Outdoor Sound Power Total UnitARI Octavebands Rating Unit Weighted ARI Octave Bands Unit Rating1100 Rpm Bhp1200 1300Rpm Bhp Watts Watts Rpm Bhp 1200 Rpm Bhp Watts1600 17001642 2333 1704 Rpm Bhp Watts 15002600 Watts Rpm Bhp 18002700 2800Bhp 600 Bhp Watts Rpm2700 2800 2900 3000 Watts Rpm Bhp 900 Bhp Watts 900Watts Rpm Bhp Watts 1700 1800 1900 20001900 2000 2100 2200 2300 2400 2500 800 350 904 438 999 535 1087 640 1169 753 913 569 913 569 1010 715 Refrigerant Service Ports Internal WiringUnit Preparation Gas PipingMain Burners Compressor RotationCooling Heating Safety ReliefVentilation Continuous Fan Operating SequenceHeating Units With Economi$er Subcooling ModeHot Gas Reheat Mode Evaporator Coil CleaningCondenser Coil One-Row CoilsEconoMi$er IV Adjustment Condenser-Fan AdjustmentHigh Pressure Switch Loss-of-Charge SwitchPerfect Humidity System Charging Low Charge CoolingC06142 Flue Gas Passageways 581C 3 TON Charging Chart 581C 5 TON Charging Chart LED Error Code Description Limit SwitchRemoval and Replacement of Gas Train See Combustion-Air BlowerReplacement Parts OFM Economi$er IV Troubleshooting Unit TroubleshootingLED Error Code Service Analysis Economi$er IV Troubleshooting CompletionSymptom Cause Remedy LED OFFProblem Cause Remedy Heating Service AnalysisCooling Service Analysis Inputs Outputs EconoMi$er IV Input/Output LogicCatalog No. II581B---C---36---1 Preliminary Information