Table 19—Fan Performance 581B 048, 581C 048 — Vertical Discharge Units; High-Static Motor (Belt Drive)*

AIRFLOW

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

CFM

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1200

666

0.26

257

778

0.37

367

871

0.47

471

952

0.57

572

1025

0.67

670

1300

701

0.31

306

810

0.43

426

901

0.54

540

981

0.65

651

1053

0.76

760

1400

737

0.36

361

842

0.49

491

931

0.62

616

1010

0.74

738

1081

0.86

856

1500

773

0.42

422

875

0.57

564

963

0.70

699

1040

0.84

831

1110

0.96

960

1600

810

0.49

491

909

0.65

643

994

0.79

790

1070

0.94

932

1140

1.08

1070

1700

847

0.57

567

943

0.73

730

1027

0.89

888

1101

1.05

1040

1170

1.20

1189

1800

885

0.66

652

978

0.83

826

1060

1.00

994

1133

1.16

1157

1200

1.32

1316

1900

923

0.75

745

1014

0.94

930

1093

1.11

1109

1165

1.29

1283

1231

1.46

1453

2000

962

0.85

847

1049

1.05

1043

1127

1.24

1233

1198

1.42

1417

1263

1.61

1598

AIRFLOW

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

CFM

 

1.2

 

 

 

1.4

 

 

1.6

 

 

 

 

1.8

 

 

2.0

 

Rpm

Bhp

Watts

 

Rpm

Bhp

Watts

Rpm

Bhp

 

Watts

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1200

1093

0.77

767

 

1155

0.87

861

1213

0.96

 

955

 

1268

1.05

1047

1321

1.14

1137

1300

1119

0.87

866

 

1181

0.98

970

1239

1.08

 

1073

 

1294

1.18

1175

1346

1.28

1275

1400

1147

0.98

972

 

1208

1.09

1086

1265

1.21

 

1199

 

1320

1.32

1310

1371

1.43

1419

1500

1175

1.09

1086

 

1235

1.22

1209

1292

1.34

 

1332

 

1346

1.46

1452

1397

1.58

1572

1600

1204

1.21

1207

 

1263

1.35

1340

1320

1.48

 

1472

 

1373

1.61

1603

1424

1.74

1732

1700

1233

1.34

1336

 

1292

1.49

1480

1348

1.63

 

1622

 

1401

1.77

1762

1451

1.91

1901

1800

1262

1.48

1473

 

1321

1.64

1627

1376

1.79

 

1779

 

1428

1.94

1930

1479

2.09

2078

1900

1293

1.63

1620

 

1350

1.79

1784

1405

1.96

 

1946

 

1457

2.12

2106

1506

2.28

2265

2000

1323

1.79

1776

 

1380

1.96

1950

1434

2.13

 

2123

 

1486

2.31

2293

NOTES:

 

 

 

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

1. Grey cells indicate field-supplied drive is required.

 

 

 

Bhp — Brake Horsepower

 

 

 

 

2. Maximum continuous bhp is 2.40.

 

 

 

 

 

Watts — Input Watts to Motor

 

 

 

 

3. See general fan performance notes.

 

 

 

 

*Motor drive range: 1075 to 1455 rpm. All other rpms require field-supplied

 

 

 

 

 

 

 

 

 

 

drive.

 

 

 

 

 

 

Table 20—Fan Performance 581B 060, 581C 060 Single-Phase — Vertical Discharge Units;

Standard Motor (Belt Drive)*

AIRFLOW

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

CFM

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1500

848

0.42

371

968

0.55

486

1069

0.68

600

1158

0.80

715

1238

0.94

831

1600

887

0.49

433

1004

0.63

556

1103

0.76

678

1190

0.90

800

1269

1.04

922

1700

927

0.57

502

1040

0.71

633

1137

0.86

763

1223

1.00

892

1302

1.15

1022

1800

967

0.65

579

1077

0.81

718

1172

0.96

856

1257

1.12

993

1334

1.27

1130

1900

1007

0.75

663

1115

0.91

811

1208

1.08

957

1291

1.24

1101

2000

1048

0.85

757

1153

1.03

913

1244

1.20

1066

2100

1090

0.97

859

1191

1.15

1023

2200

1131

1.09

970

1230

1.29

1143

2300

1173

1.23

1091

2400

2500

AIRFLOW

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

CFM

 

1.2

 

 

1.4

 

 

1.6

 

 

 

1.8

 

 

2.0

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1500

1312

1.07

948

1380

1.20

1067

 

1600

1342

1.18

1047

 

1700

1374

1.30

1153

 

1800

 

1900

 

2000

 

2100

 

2200

 

2300

 

2400

 

2500

 

NOTES:

 

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

1. Grey cells indicate field-supplied drive is required.

 

 

Bhp — Brake Horsepower

 

 

 

 

2. Maximum continuous bhp is 1.30.

 

 

 

 

Watts — Input Watts to Motor

 

 

 

 

3. See general fan performance notes.

 

 

 

 

*Motor drive range: 1035 to 1460 rpm. All other rpms require field-supplied

 

 

 

 

 

 

 

 

drive.

 

 

 

 

 

 

581B,C

31

Image 31
Contents Installation Instructions Rig and Place Unit Install External Trap for Condensate DrainProvide Unit Support Field Fabricate DuctworkRoof Curb Details Install Gas Piping Install Flue HoodRoof Curb Alignment 581B 036-072 Base Unit Dimensions 581C 024-060 Base Unit Dimensions Make Electrical Connections Field Power SupplyField Control Wiring Heat Anticipator SettingsBase Unit 581B Physical Data 581BUnit Size 581B Base Unit 581C Physical Data 581CUnit Size 581C Power Wiring Connections 581C024---060 Electrical Data 581CElectrical Data 581B Manual Outdoor Damper Adjust Factory-Installed OptionsAssembly Perfect Humidity Adaptive Dehumidification SystemTypical Perfect Humidity t Adaptive Dehumidification System Outdoor-Air Damper With Hood Attached Outdoor Air Lockout Sensor Supply Air Temperature SAT SensorSupply Air Sensor Temperature Resistance Values Temperature FDifferential Dry Bulb Control Economi$er IV Control ModesOutdoor Dry Bulb Changeover Economi$er IV Sensor UsageEconoMi$er IV Wiring Minimum Position Control Exhaust Set Point AdjustmentThermostats Damper MovementDemand Controlled Ventilation DCV Enthalpy Changeover Set Points Belt Drive Motors Dehumidification of Fresh Air with DCV ControlBelt Drive Motor Mounting CO2Sensor Standard SettingsEvaporator-Fan Motor Data High-Static Motors 581B Fan Rpm at Motor Pulley Setting With High-Static MotorAccessory Static Pressure Evaporator-Fan Motor Data Standard MotorARI Octave Bands Unit Rating 581B Outdoor Sound Power Total Unit581C Outdoor Sound Power Total Unit ARI Octavebands Rating Unit Weighted1300 Rpm Bhp1100 1200Rpm Bhp Watts 1700 Rpm Bhp WattsWatts Rpm Bhp 1200 16001642 2333 1704 Rpm Bhp Watts 15002800 Watts Rpm Bhp 18002600 27002700 2800 2900 3000 Bhp Watts RpmBhp 600 Watts Rpm Bhp Watts 900Watts Rpm Bhp 900 Bhp Watts 1700 1800 1900 20001900 2000 2100 2200 2300 2400 2500 800 350 904 438 999 535 1087 640 1169 753 913 569 913 569 1010 715 Gas Piping Internal WiringRefrigerant Service Ports Unit PreparationCooling Compressor RotationMain Burners Operating Sequence Safety ReliefHeating Ventilation Continuous FanHot Gas Reheat Mode Subcooling ModeHeating Units With Economi$er One-Row Coils CleaningEvaporator Coil Condenser CoilLoss-of-Charge Switch Condenser-Fan AdjustmentEconoMi$er IV Adjustment High Pressure SwitchPerfect Humidity System Charging Low Charge CoolingC06142 Flue Gas Passageways 581C 3 TON Charging Chart 581C 5 TON Charging Chart Combustion-Air Blower Limit SwitchLED Error Code Description Removal and Replacement of Gas Train SeeReplacement Parts OFM Economi$er IV Troubleshooting Unit TroubleshootingLED OFF Economi$er IV Troubleshooting CompletionLED Error Code Service Analysis Symptom Cause RemedyProblem Cause Remedy Heating Service AnalysisCooling Service Analysis Inputs Outputs EconoMi$er IV Input/Output LogicCatalog No. II581B---C---36---1 Preliminary Information