Omron ZS-MDC user manual Orientation when Installing the Multi-Controller, Warming Up

Page 9

Introduction

Precautions for Correct Use

(3) Orientation when Installing the Multi-Controller

To improve heat radiation, install the Multi-Controller only in the orientation shown below.

Right

Do not install the Multi-Controller in the following orientations.

WrongWrong

(4)Warming Up

After turning ON the power supply, allow the product to stand for at least 30 minutes before use. The circuits are still unstable immediately after the power supply is turned ON, so measured values may fluctuate gradually.

(5)Maintenance and Inspection

Do not use thinner, benzene, acetone or kerosene to clean the Multi-Controller.

Introduction

ZS-MDC

User’s Manual

7

Image 9
Contents Smart Sensor Introduction How to Switch the Display Language to EnglishSmart Sensors Multi-Controller ZS-MDC EctionRead and Understand this Document Suitability for USE Dimensions and Weights Installation Environment Power Supply and WiringOthers Installation Site Precautions for Correct UseOrientation when Installing the Multi-Controller Maintenance and InspectionWarming Up Format Editors NoteVisual Aids Meaning of SymbolsMemo Contents Introduction Contents Features Supports Connection to Up to 9 Sensor Controllers Multi-Controller FeaturesWide Range of Logic Operation Functions Completely Digitally Based Logic Operation ProcessingSame Compact Size as Sensor Controller USB ConnectionDedicated Software SmartMonitor Zero Measurement of Workpiece Thickness at Multiple Locations Multi-Controller ApplicationsMeasurement of Stepped Workpieces Measurement of Average Workpiece HeightMeasurement of Workpiece Flatness Measurement of Workpiece StrainBatch-acquisition of Multi-point Measurement Data State of gang-mounted Sensor Controllers can be monitored Gang-mounted Sensor Controllers can be set upZS-MDC11/MDC41 Basic ConfigurationPart Names and Functions Threshold Selector Switch Mode SwitchLOW indicator Pass indicatorMemo Installation & Connection Installation & ConnectionChecking the installation environment About Installation and ConnectionChecking the installation site About the power supplyAttaching the ferrite core Multi-ControllerInstalling the Multi-Controller About channel No. when controllers are gang-mountedCH0 CH1 CH2 CH3 CH9 Installing on the DIN track Installation procedurePFP-M Open the connector cover on the con- troller Removal procedureInstall the cover on the coupler of the controller Installation & Connection Mounting on a panel InstallationController with Panel Mount Adapters Install the Multi-Controller and SensorAttached onto the panel from the front Hook the hooks of the mounting fixtureAbout the I/O cable Wiring the I/O cableOUT4 Busy output OUT3 Enable outputLinear output Linear GNDNPN type ZS-MDC11 Installation & Connection Circuit DiagramsPNP type ZS-MDC41 Memo Setup Installation and Connection Setting FlowWhen a Problem Occurs About Setup Switching ModesBasic Knowledge for Operation Displays and Key Operations FUN ModePress the Menu key to return to the top menu Press function key 2 representing onThresh RUN ModeVoltage Current ResoluTeaching Direct Teach ModeList of Setting Items FUN ModeWhen TASK1 is selected Adjust TimerCOM Mode SET NO-MEASBank System When other than TASK1 is selectedTeach Mode RUN ModeSelecting Tasks Setting Assignments Setting Logic Operation Methods Switching banks by external signal input Setting I/O AssignmentsChanging Linear Output Assignments Changing Output AssignmentsAbout Digital Output TASK3 TASK4Memo Application Setting Examples Application Setting ExamplesExamples Application SettingSet the expression of TASK1 Select TASK1SENSING-CALC-CALC-MAX-MIN Application Measuring the Relative Difference between StepsSet the expression of TASK1 Following the same procedure as 2 to 3, set Up TASK3To linear-output the operation result I/O SET-I/O SET-ANALOG Measuring the Reference Difference between Steps Following the same procedure as 2 to 3, set Up TASK2 Select TASK1 or TASK2 depending onDetails to be output CH0 CH1 CH2 CH3 CH9 Measuring FlatnessTASK12 TASK2 TASK34 TASK4 Input a Input B Input C Measuring the Average Height Select TASK1 so that the average value can be linear-output Average to ON, and other inputs to OFFCH0 CH1 CH2 CH3 CH4 Measuring the Twist of a WorkpieceInput X Input D Input Y Input C Select TASK3 so that the twist value can be linear-output Select TASK3 so that the judgment on the twist can be outputCH0 CH1 CH2 CH3 Measuring the Warp of a WorkpieceSelect TASK1 Application Setting Examples Select TASK2 so that the warp value can be linear-output Select TASK2 so that the judgment on the warp can be outputMemo Appendix Troubleshooting When Error Is Displayed on the Main Display Error Messages and CountermeasuresWhen all digits on the main display and sub-display blink OthersOr more of the rated measuring range Glossary Multi-Controller Specifications and External DimensionsPASS/LOW ZS-MDC11 ZS-MDC41Shock resistance destructive ZS-XPM1/XPM2 Panel Mount AdaptersZS-XRS2 RS-232C Cable for Connecting to a Personal ComputerZS-XCN Controller Link UnitVersion Up Information Ver1.00 to Ver1.50Ver1.50 to Ver2.00 Section Index IndexUSB Memo Z209-E1-01 Revision HistoryTerms and Conditions of Sale Omron Electronics LLC