Specifications and External Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

ZS-MDC11

ZS-MDC41

 

 

 

I/O type

 

 

NPNtype

PNPtype

 

 

 

 

 

 

 

 

 

No. of samples to average

1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048, or 4096

 

 

 

 

 

 

 

 

 

Number of mounted Sensor Heads

Cannot be connected

 

 

 

 

 

 

 

 

 

 

Connectable version of Sensor Controller

Ver2.0 or later

 

 

 

 

 

 

 

 

 

 

Number of mounted Sensor Controllers

Max. 9

 

 

 

 

 

 

 

 

(The Controller Link Unit is needed for gang-mounting.)

 

 

 

 

 

 

 

 

 

 

Exte

Connection method

Serial I/O or connector

 

 

 

 

rnal

 

 

 

Prewired (standard cable length: 2 m)

 

 

 

 

I/F

 

 

 

 

 

 

 

 

Serial I/O

 

USB2.0

1 port, FULL SPEED [12 Mbps], MINI-B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232C

1 port, max. 115200 bps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

 

Judgment output

NPN open-collector, 30 VDC, 50 mA

PNPopen-collector 50 mA

 

 

 

 

 

 

3 outputs: HIGH/

max. residual voltage; 1.2 V max.

max. residual voltage;1.2V

 

 

 

 

 

 

PASS/LOW

 

max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Linear output

Selectable from voltage/current

 

 

 

 

 

 

 

 

(selected by slide switch on base)

 

 

 

 

 

 

 

 

• At voltage output: -10 to +10 V, output impedance: 40

 

 

 

 

 

 

 

• At current output: 4 to 20 mA, max. load resistance: 300

 

 

 

 

 

 

 

 

 

 

Section

 

 

Input

 

tion/cancel

OFF: Open (leakage current: 0.1 mA

age -1.5 V

 

 

 

 

ZERO reset input

ON: Short-circuited with 0V terminal

ON: Supply voltage short-cir-

 

 

 

 

 

 

ZERO reset execu-

or 1.5 V max.

cuited or within supply volt-

 

 

 

 

 

 

 

max.)

OFF: Open (leakage current:

 

5

 

 

 

 

Timing input

 

 

 

 

 

 

0.1 mA max.)

 

APPENDIX

 

 

 

 

Sample cycle speci-

 

 

 

 

 

 

 

 

 

 

 

 

 

fied when hold func-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tion is enabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RESET input

 

 

 

 

 

 

 

 

Reset of hold state

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status indicators

 

 

HIGH (orange), PASS (green), LOW (orange),

 

 

 

 

 

 

 

LDON (green), ZERO (green), ENABLE (green)

 

 

 

 

 

 

 

 

 

 

 

Segment display

 

Main display

8-segment red display, 6 digits

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sub-display

8-segment green display, 6 digits

 

 

 

 

 

 

 

 

 

 

 

 

 

LCD

 

 

 

16 digits x 2 rows, color of characters: green, resolution per charac-

 

 

 

 

 

 

 

ter: 5 x 8 pixel matrix

 

 

 

 

 

 

 

 

 

 

 

 

Setting input

 

Setting keys

Direction keys (UP/DOWN/LEFT/RIGHT), SET key, ESC key,

 

 

 

 

 

 

 

MENU key, function keys (1 to 4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slide switch

Threshold switch (H/L 2-state)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODE switch (FUN/TEACH/RUN 3-state)

 

 

 

 

 

 

 

 

 

 

Power supply voltage

21.6 V to 26.4 V (including ripple)

 

 

 

 

 

 

 

 

 

 

Current consumption

0.5 A max.

 

 

 

 

 

 

 

 

 

Insulation resistance

Across all lead wires and controller case: 20 M (by 250 V megger)

 

 

 

 

 

 

 

 

 

 

Dialectic strength

 

 

Across all lead wires and controller case, 1000 VAC, 50/60 Hz, 1

 

 

 

 

 

 

 

min

 

 

 

 

 

 

 

 

 

 

 

Noise immunity

 

 

1500 V peak-to-peak, pulse width 0.1 s/1 s, rising edge: 1 ns

 

 

 

 

 

 

 

pulse

 

 

 

 

 

 

 

 

 

Vibration resistance (destructive)

10 to 150 Hz, 0.7-mm double amplitude, 80 min each in X, Y, and Z

 

 

 

 

 

 

 

directions

 

 

 

 

 

 

 

 

 

 

 

 

ZS-MDC

User’s Manual

5-7

Image 83
Contents Smart Sensor Introduction How to Switch the Display Language to EnglishSmart Sensors Multi-Controller ZS-MDC EctionRead and Understand this Document Suitability for USE Dimensions and Weights Others Installation EnvironmentPower Supply and Wiring Installation Site Precautions for Correct UseWarming Up Orientation when Installing the Multi-ControllerMaintenance and Inspection Format Editors NoteVisual Aids Meaning of SymbolsMemo Contents Introduction Contents Features Completely Digitally Based Logic Operation Processing Multi-Controller FeaturesSupports Connection to Up to 9 Sensor Controllers Wide Range of Logic Operation FunctionsDedicated Software SmartMonitor Zero Same Compact Size as Sensor ControllerUSB Connection Measurement of Average Workpiece Height Multi-Controller ApplicationsMeasurement of Workpiece Thickness at Multiple Locations Measurement of Stepped WorkpiecesBatch-acquisition of Multi-point Measurement Data Measurement of Workpiece FlatnessMeasurement of Workpiece Strain State of gang-mounted Sensor Controllers can be monitored Gang-mounted Sensor Controllers can be set upZS-MDC11/MDC41 Basic ConfigurationPart Names and Functions Pass indicator Mode SwitchThreshold Selector Switch LOW indicatorMemo Installation & Connection Installation & ConnectionAbout the power supply About Installation and ConnectionChecking the installation environment Checking the installation siteAttaching the ferrite core Multi-ControllerCH0 CH1 CH2 CH3 CH9 Installing the Multi-ControllerAbout channel No. when controllers are gang-mounted PFP-M Installing on the DIN trackInstallation procedure Install the cover on the coupler of the controller Open the connector cover on the con- trollerRemoval procedure Installation & Connection Mounting on a panel InstallationHook the hooks of the mounting fixture Install the Multi-Controller and SensorController with Panel Mount Adapters Attached onto the panel from the frontAbout the I/O cable Wiring the I/O cableLinear GND OUT3 Enable outputOUT4 Busy output Linear outputNPN type ZS-MDC11 Installation & Connection Circuit DiagramsPNP type ZS-MDC41 Memo Setup Installation and Connection Setting FlowWhen a Problem Occurs Basic Knowledge for Operation About SetupSwitching Modes Displays and Key Operations FUN ModePress the Menu key to return to the top menu Press function key 2 representing onResolu RUN ModeThresh Voltage CurrentTeaching Direct Teach ModeWhen TASK1 is selected List of Setting ItemsFUN Mode SET NO-MEAS TimerAdjust COM ModeBank System When other than TASK1 is selectedTeach Mode RUN ModeSelecting Tasks Setting Assignments Setting Logic Operation Methods Switching banks by external signal input Setting I/O AssignmentsTASK3 TASK4 Changing Output AssignmentsChanging Linear Output Assignments About Digital OutputMemo Application Setting Examples Application Setting ExamplesExamples Application SettingSet the expression of TASK1 Select TASK1SENSING-CALC-CALC-MAX-MIN Application Measuring the Relative Difference between StepsSet the expression of TASK1 Following the same procedure as 2 to 3, set Up TASK3To linear-output the operation result I/O SET-I/O SET-ANALOG Measuring the Reference Difference between Steps Details to be output Following the same procedure as 2 to 3, set Up TASK2Select TASK1 or TASK2 depending on CH0 CH1 CH2 CH3 CH9 Measuring FlatnessTASK12 TASK2 TASK34 TASK4 Input a Input B Input C Measuring the Average Height Select TASK1 so that the average value can be linear-output Average to ON, and other inputs to OFFCH0 CH1 CH2 CH3 CH4 Measuring the Twist of a WorkpieceInput X Input D Input Y Input C Select TASK3 so that the twist value can be linear-output Select TASK3 so that the judgment on the twist can be outputCH0 CH1 CH2 CH3 Measuring the Warp of a WorkpieceSelect TASK1 Application Setting Examples Select TASK2 so that the warp value can be linear-output Select TASK2 so that the judgment on the warp can be outputMemo Appendix Troubleshooting Others Error Messages and CountermeasuresWhen Error Is Displayed on the Main Display When all digits on the main display and sub-display blink Or more of the rated measuring range Glossary Multi-Controller Specifications and External DimensionsPASS/LOW ZS-MDC11 ZS-MDC41Shock resistance destructive ZS-XPM1/XPM2 Panel Mount AdaptersZS-XRS2 RS-232C Cable for Connecting to a Personal ComputerZS-XCN Controller Link UnitVer1.50 to Ver2.00 Version Up InformationVer1.00 to Ver1.50 Section Index IndexUSB Memo Z209-E1-01 Revision HistoryTerms and Conditions of Sale Omron Electronics LLC