Omron ZS-MDC user manual Teach Mode, Teaching Direct

Page 46

Section 3 SETUP

Section 3

About Setup

Key

 

Measured Value Display

Display Customize Menu

UP key

 

UP key: Executes trigger input.

The function changes depend-

DOWN key

 

DOWN key: Executes reset

ing on the settings.

 

 

input.

• Changes numerical values.

 

 

 

• Changes text.

 

 

 

 

MENU key

 

Displays the display customize

Returns to the top of the display

 

 

menu.

customize menu.

 

 

 

 

SET key

 

Executes a zero reset.

Applies numerical value settings.

 

 

 

 

ESC key

 

Hold down for at least two sec-

Returns to the previous menu.

 

 

onds to cancel a zero reset.

When the top menu is displayed,

 

 

 

returns to the measured value

 

 

 

display.

 

 

 

 

TEACH Mode

In this mode, the measured value is displayed at all times on the main display. The threshold values are displayed on the sub-display. Which of the HIGH or LOW threshold values is displayed changes according to the setting of the threshold selector switch.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEACH MODE

 

 

 

 

 

 

 

TEACH MODE

 

MENU : TEACHING

 

 

 

 

 

 

 

: DIRECT IN

 

 

 

 

 

 

 

 

Displayed alternately

Key Operations

Key

TEACHING

DIRECT IN

Function keys

Not used

Not used

LEFT key

Not used

Selects the digit in the threshold

RIGHT key

 

numerical value.

UP key

Not used

Changes the threshold numerical

DOWN key

 

value.

MENU key

Registers the measured value

Not used

 

when this key is pressed as the

 

 

threshold value.

 

SET key

Not used

Applies the newly set threshold

 

 

value.

ESC key

Not used

Cancels the newly set threshold

 

 

value.

3-8

ZS-MDC

User’s Manual

Image 46
Contents Smart Sensor How to Switch the Display Language to English IntroductionEction Smart Sensors Multi-Controller ZS-MDCRead and Understand this Document Suitability for USE Dimensions and Weights Power Supply and Wiring Installation EnvironmentOthers Precautions for Correct Use Installation SiteMaintenance and Inspection Orientation when Installing the Multi-ControllerWarming Up Editors Note FormatMeaning of Symbols Visual AidsMemo Contents Introduction Contents Features Wide Range of Logic Operation Functions Multi-Controller FeaturesSupports Connection to Up to 9 Sensor Controllers Completely Digitally Based Logic Operation ProcessingUSB Connection Same Compact Size as Sensor ControllerDedicated Software SmartMonitor Zero Measurement of Stepped Workpieces Multi-Controller ApplicationsMeasurement of Workpiece Thickness at Multiple Locations Measurement of Average Workpiece HeightMeasurement of Workpiece Strain Measurement of Workpiece FlatnessBatch-acquisition of Multi-point Measurement Data Gang-mounted Sensor Controllers can be set up State of gang-mounted Sensor Controllers can be monitoredBasic Configuration ZS-MDC11/MDC41Part Names and Functions LOW indicator Mode SwitchThreshold Selector Switch Pass indicatorMemo Installation & Connection Installation & ConnectionChecking the installation site About Installation and ConnectionChecking the installation environment About the power supplyMulti-Controller Attaching the ferrite coreAbout channel No. when controllers are gang-mounted Installing the Multi-ControllerCH0 CH1 CH2 CH3 CH9 Installation procedure Installing on the DIN trackPFP-M Removal procedure Open the connector cover on the con- trollerInstall the cover on the coupler of the controller Installation & Connection Installation Mounting on a panelAttached onto the panel from the front Install the Multi-Controller and SensorController with Panel Mount Adapters Hook the hooks of the mounting fixtureWiring the I/O cable About the I/O cableLinear output OUT3 Enable outputOUT4 Busy output Linear GNDCircuit Diagrams NPN type ZS-MDC11 Installation & ConnectionPNP type ZS-MDC41 Memo Setup Setting Flow Installation and ConnectionWhen a Problem Occurs Switching Modes About SetupBasic Knowledge for Operation FUN Mode Displays and Key OperationsPress function key 2 representing on Press the Menu key to return to the top menuVoltage Current RUN ModeThresh ResoluTeach Mode Teaching DirectFUN Mode List of Setting ItemsWhen TASK1 is selected COM Mode TimerAdjust SET NO-MEASWhen other than TASK1 is selected Bank SystemRUN Mode Teach ModeSelecting Tasks Setting Assignments Setting Logic Operation Methods Setting I/O Assignments Switching banks by external signal inputAbout Digital Output Changing Output AssignmentsChanging Linear Output Assignments TASK3 TASK4Memo Application Setting Examples Application Setting ExamplesApplication Setting ExamplesSelect TASK1 Set the expression of TASK1SENSING-CALC-CALC-MAX-MIN Measuring the Relative Difference between Steps ApplicationFollowing the same procedure as 2 to 3, set Up TASK3 Set the expression of TASK1To linear-output the operation result I/O SET-I/O SET-ANALOG Measuring the Reference Difference between Steps Select TASK1 or TASK2 depending on Following the same procedure as 2 to 3, set Up TASK2Details to be output Measuring Flatness CH0 CH1 CH2 CH3 CH9TASK12 TASK2 TASK34 TASK4 Input a Input B Input C Measuring the Average Height Average to ON, and other inputs to OFF Select TASK1 so that the average value can be linear-outputMeasuring the Twist of a Workpiece CH0 CH1 CH2 CH3 CH4Input X Input D Input Y Input C Select TASK3 so that the judgment on the twist can be output Select TASK3 so that the twist value can be linear-outputMeasuring the Warp of a Workpiece CH0 CH1 CH2 CH3Select TASK1 Application Setting Examples Select TASK2 so that the judgment on the warp can be output Select TASK2 so that the warp value can be linear-outputMemo Appendix Troubleshooting When all digits on the main display and sub-display blink Error Messages and CountermeasuresWhen Error Is Displayed on the Main Display OthersOr more of the rated measuring range Glossary Specifications and External Dimensions Multi-ControllerZS-MDC11 ZS-MDC41 PASS/LOWShock resistance destructive Panel Mount Adapters ZS-XPM1/XPM2RS-232C Cable for Connecting to a Personal Computer ZS-XRS2Controller Link Unit ZS-XCNVer1.00 to Ver1.50 Version Up InformationVer1.50 to Ver2.00 Index Section IndexUSB Memo Revision History Z209-E1-01Terms and Conditions of Sale Omron Electronics LLC