Emerson IP2046IM, MSP400RH manual Appendix C Listing of NON-LINEAR Profiles in the MSP400, Spec.C

Page 43

APPENDIX C

LISTING OF NON-LINEAR PROFILES IN THE MSP400

 

Screen

Description

Hmax

K Factor * or

Power

20mA point if

 

Display

 

used

Flo @ max.

Factor

auto-set

 

Lin

Linear

 

-

 

User

1.0

 

-

 

SPEC.P

Special (plotted)

 

-

 

User

User

As P013

 

H. CYL.F

Horiz. Cyl. (Flat)

 

-

 

User

User

As P013

 

SPH.

Spherical

 

-

 

User

User

As P013

 

H. CYL.D

Horiz. Cyl. (Dome)

 

-

 

User

User

As P013

3/2

Flume (3/2)

 

-

 

User

1.5

User

5/2

V-Notch (5/2)

 

-

 

User

2.5

User

 

nnanna

Manning Formula

 

-

 

User

User

As P013

 

SPEC.C

Special (calculated)

 

-

 

User

User

User

 

 

 

m

 

ft

Metric

Imp.

 

m3/hr

 

gal/min

 

PAr 1

Parshall 1 (1’)

0.75

 

2.5

2487

1795

1.522

1610

 

7240

 

PAr 2

Parshall 2 (2’)

0.75

 

2.5

5143

3590

1.550

3290

 

14900

 

PAr 3

Parshall 3 (3’)

0.75

 

2.5

7863

5386

1.566

5010

 

22600

 

PAr 4

Parshall 4 (4’)

0.75

 

2.5

10630

7181

1.578

6750

 

30500

 

PAr 5

Parshall 5 (5’)

0.75

 

2.5

13440

8976

1.587

8510

 

38400

 

PAr 6

Parshall 6 (6’)

0.75

 

2.5

16280

10770

1.595

10300

 

46400

 

PAr 8

Parshall 8 (8’)

0.75

 

2.5

22010

14360

1.607

13900

 

62600

 

 

 

 

 

 

 

 

 

FF 01

Flume Flat 1 (m)

0.102

134.7877

1.5

 

9

 

FF 02

Flume Flat 2 (m)

0.191

178.2664

1.5

 

36

 

FF 03

Flume Flat 3 (m)

0.267

313.4177

1.5

 

90

 

FF 04

Flume Flat 4 (m)

0.406

541.7157

1.5

 

360

 

FF 05

Flume Flat 5 (m)

0.635

811.1058

1.5

 

900

 

FF 06

Flume Flat I

0.200

132.2

1.5

 

30

 

FF 07

Flume Flat II

0.250

177.7

1.5

 

60

 

FF 08

Flume Flat III

0.300

217.58

1.5

 

90

 

FF 09

Flume Flat III bis

0.3333

328.35

1.5

 

200

 

FF 10

Flume Flat III ter

0.400

272.0

1.5

 

200

 

FF 11

Flume Flat IV

0.400

352.1726

1.5

 

180

 

FF 12

Flume Flat V

0.500

442.932

1.5

 

360

 

FF 13

Flume Flat V bis

0.400

400.5

1.5

 

320

 

FF 14

Flume Flat VI

0.540

499.0569

1.5

 

720

 

FF 15

Flume Flat VII

0.700

623.7

1.5

1080

 

FF 16

Flume Flat VIII

0.600

881.16

1.5

1440

 

FF 17

Flume Flat VIII bis

0.666

798.0

1.5

1500

 

FF 18

Flume Flat IX

0.800

1065.186

1.5

1800

 

FF 19

Flume Flat IX bis

0.733

814.8

1.5

1700

 

FF 20

Flume Flat X

0.867

1322.2761

1.5

3600

 

FF 21

Flume Flat X bis

1.200

1609.0

1.5

7500

 

FF 22

Flume Flat X ter

0.959

1064.884

1.5

3500

 

FF 23

Flume Flat XI

1.200

1650.99

1.5

7200

 

FP 01

Flume Parabolic 1

0.200

15878.5

2.3

 

20

 

FP 02

Flume Parabolic 2

0.250

17591.1

2.3

 

40

 

FP 03

Flume Parabolic 3

0.310

11645.6

2.2

 

90

 

FP 04

Flume Parabolic 4

0.380

13669.5

2.2

 

180

 

FP 05

Flume Parabolic 5

0.460

9802.7

2.1

 

360

 

FP 06

Flume Parabolic 6

0.600

11367.8

2.1

 

720

 

FP 07

Flume Parabolic 7

0.800

12227.7

2.1

1400

Notes :

i). SPEC.P and SPEC.C ONLY DISPLAY IF POPULATED BY EXTERNAL MASTER. Refer to Section 4.4.4.1.

ii). Where shown “User” indicates user required to input the appropriate data.

43

IP2046/IM

Nov 2006

 

Image 43
Contents Mobrey Contents Introduction Pvdf Wetside Installation IP2046/IM IP2046/IM IP2046/IM Do not USE Housing to Tighten Ptfe RL1 Spst IP2046/IM Alarm IP2046/IM IP2046/IM Selecting the units of measurement Screen display 20/4 Ullage Liquid level SPEC. P CYL.F Scale LEUEL@ max Maximum flow entry Screen display IP2046/IM IP2046/IM IP2046/IM IP2046/IM IP2046/IM Loop IP2046/IM IP2046/IM IP2046/IM IP2046/IM IP2046/IM IP2046/IM IP2046/IM Appendix A1 Main Menu Programming DutyAppendix A1 SEt20Leuel Appendix A2 Diagnostics MenuAppendix A3 Commissioning / Loop Test Menu LoopAppendix A4 Engineering MenuProF Appendix B Default Value Listing Main Menu ParametersDEAd Default Value Listing Engineering ParametersSPEC.C Appendix C Listing of NON-LINEAR Profiles in the MSP400Appendix D Hart Communications with the MSP400 Table of MSP400 Parameters IP2046/IM IP2046/IM Instruction & maintenance leaflet