APPENDIX C
LISTING OF NON-LINEAR PROFILES IN THE MSP400
| Screen | Description | Hmax | K Factor * or | Power | 20mA point if | |||||
| Display |
| used | Flo @ max. | Factor | ||||||
| Lin | Linear |
| - |
| User | 1.0 |
| - | ||
| SPEC.P | Special (plotted) |
| - |
| User | User | As P013 | |||
| H. CYL.F | Horiz. Cyl. (Flat) |
| - |
| User | User | As P013 | |||
| SPH. | Spherical |
| - |
| User | User | As P013 | |||
| H. CYL.D | Horiz. Cyl. (Dome) |
| - |
| User | User | As P013 | |||
3/2 | Flume (3/2) |
| - |
| User | 1.5 | User | ||||
5/2 |
| - |
| User | 2.5 | User | |||||
| nnanna | Manning Formula |
| - |
| User | User | As P013 | |||
| SPEC.C | Special (calculated) |
| - |
| User | User | User | |||
|
|
| m |
| ft | Metric | Imp. |
| m3/hr |
| gal/min |
| PAr 1 | Parshall 1 (1’) | 0.75 |
| 2.5 | 2487 | 1795 | 1.522 | 1610 |
| 7240 |
| PAr 2 | Parshall 2 (2’) | 0.75 |
| 2.5 | 5143 | 3590 | 1.550 | 3290 |
| 14900 |
| PAr 3 | Parshall 3 (3’) | 0.75 |
| 2.5 | 7863 | 5386 | 1.566 | 5010 |
| 22600 |
| PAr 4 | Parshall 4 (4’) | 0.75 |
| 2.5 | 10630 | 7181 | 1.578 | 6750 |
| 30500 |
| PAr 5 | Parshall 5 (5’) | 0.75 |
| 2.5 | 13440 | 8976 | 1.587 | 8510 |
| 38400 |
| PAr 6 | Parshall 6 (6’) | 0.75 |
| 2.5 | 16280 | 10770 | 1.595 | 10300 |
| 46400 |
| PAr 8 | Parshall 8 (8’) | 0.75 |
| 2.5 | 22010 | 14360 | 1.607 | 13900 |
| 62600 |
|
|
|
|
|
|
|
| ||||
| FF 01 | Flume Flat 1 (m) | 0.102 | 134.7877 | 1.5 |
| 9 | ||||
| FF 02 | Flume Flat 2 (m) | 0.191 | 178.2664 | 1.5 |
| 36 | ||||
| FF 03 | Flume Flat 3 (m) | 0.267 | 313.4177 | 1.5 |
| 90 | ||||
| FF 04 | Flume Flat 4 (m) | 0.406 | 541.7157 | 1.5 |
| 360 | ||||
| FF 05 | Flume Flat 5 (m) | 0.635 | 811.1058 | 1.5 |
| 900 | ||||
| FF 06 | Flume Flat I | 0.200 | 132.2 | 1.5 |
| 30 | ||||
| FF 07 | Flume Flat II | 0.250 | 177.7 | 1.5 |
| 60 | ||||
| FF 08 | Flume Flat III | 0.300 | 217.58 | 1.5 |
| 90 | ||||
| FF 09 | Flume Flat III bis | 0.3333 | 328.35 | 1.5 |
| 200 | ||||
| FF 10 | Flume Flat III ter | 0.400 | 272.0 | 1.5 |
| 200 | ||||
| FF 11 | Flume Flat IV | 0.400 | 352.1726 | 1.5 |
| 180 | ||||
| FF 12 | Flume Flat V | 0.500 | 442.932 | 1.5 |
| 360 | ||||
| FF 13 | Flume Flat V bis | 0.400 | 400.5 | 1.5 |
| 320 | ||||
| FF 14 | Flume Flat VI | 0.540 | 499.0569 | 1.5 |
| 720 | ||||
| FF 15 | Flume Flat VII | 0.700 | 623.7 | 1.5 | 1080 | |||||
| FF 16 | Flume Flat VIII | 0.600 | 881.16 | 1.5 | 1440 | |||||
| FF 17 | Flume Flat VIII bis | 0.666 | 798.0 | 1.5 | 1500 | |||||
| FF 18 | Flume Flat IX | 0.800 | 1065.186 | 1.5 | 1800 | |||||
| FF 19 | Flume Flat IX bis | 0.733 | 814.8 | 1.5 | 1700 | |||||
| FF 20 | Flume Flat X | 0.867 | 1322.2761 | 1.5 | 3600 | |||||
| FF 21 | Flume Flat X bis | 1.200 | 1609.0 | 1.5 | 7500 | |||||
| FF 22 | Flume Flat X ter | 0.959 | 1064.884 | 1.5 | 3500 | |||||
| FF 23 | Flume Flat XI | 1.200 | 1650.99 | 1.5 | 7200 | |||||
| FP 01 | Flume Parabolic 1 | 0.200 | 15878.5 | 2.3 |
| 20 | ||||
| FP 02 | Flume Parabolic 2 | 0.250 | 17591.1 | 2.3 |
| 40 | ||||
| FP 03 | Flume Parabolic 3 | 0.310 | 11645.6 | 2.2 |
| 90 | ||||
| FP 04 | Flume Parabolic 4 | 0.380 | 13669.5 | 2.2 |
| 180 | ||||
| FP 05 | Flume Parabolic 5 | 0.460 | 9802.7 | 2.1 |
| 360 | ||||
| FP 06 | Flume Parabolic 6 | 0.600 | 11367.8 | 2.1 |
| 720 | ||||
| FP 07 | Flume Parabolic 7 | 0.800 | 12227.7 | 2.1 | 1400 |
Notes :
i). SPEC.P and SPEC.C ONLY DISPLAY IF POPULATED BY EXTERNAL MASTER. Refer to Section 4.4.4.1.
ii). Where shown “User” indicates user required to input the appropriate data.
43 | IP2046/IM | |
Nov 2006 | ||
|