2.2 Pressure Equipment Directive
The MSP400RH transmitter does not fall within the PED definition as enclosing a pressurised fluid, so is therefore outside the scope of the Directive.
Accordingly, the Declaration of Conformity does not list the Pressure Equipment Directive.
2.3 Specifications |
|
Materials of construction: |
|
Transducer material | PVDF |
Body & cover Material | Glass filled nylon |
Cable gland | Nylon with Nitrile cable seal |
Cover seal | Silicone rubber |
Cover screws | 316 Stainless Steel |
Transducer bodyseal | EPDM |
Electrical |
|
Supply voltage | |
Output | |
| Relays (2) : SPST rated 1A at 24Vdc |
Communications | HART Digital communications (Rev. 5) |
Earthing | None required |
Recommended Cable | Two core each 0.22 mm2 min, shielded |
Max. cable length | 3000m |
Cable resistance | 0.1 Ohm per metre length max. |
Cable gland | Suitable for cable sizes 4mm - 8mm diameter |
Operating |
|
Range | 0.45 to 11m |
Temperature |
|
Ambient | |
Wetside | |
Pressure | |
Weatherproofing | IP66/IP67 |
Certification |
|
The MSP400 range of products are Factory Mutual (Fm) certified as Process Control Equipment meeting basic electrical, mechanical and fire protection requirements (IP66/IP67).
4 | IP2046/IM | |
Nov 2006 | ||
|