SECTION 10 – GENERATOR POWER GUIDELINES

NOTE

The views in this section are intended to be representative of all engine-driven welding generators. Your unit may differ from those shown.

10-1. Selecting Equipment

1 Generator Power Receptacles

– Neutral Bonded To Frame

2 3-Prong Plug From Case

Grounded Equipment

3 2-Prong Plug From Double

Insulated Equipment

Y Do not use 2-prong plug un- less equipment is double in- sulated.

1

2

 

3

OR

Be sure equipment

has this symbol

 

 

and/or wording.

gen_pwr 11/02 – Ref. ST-159 730 / ST-800 577

10-2. Grounding Generator To Truck Or Trailer Frame

1

GND/PE2

3

Electrically bond generator frame to vehicle frame by metal-to-metal contact.

YBed liners, shipping skids, an some running gear insulate the welding generator from the ve- hicle frame. Always connect a ground wire from the generator equipment grounding terminal to bare metal on the vehicle frame as shown.

YAlways ground generator frame to vehicle frame to pre- vent electric shock and static electricity hazards.

1Equipment Grounding Terminal (On Front Panel)

2Grounding Cable (Not Supplied)

3Metal Vehicle Frame

Connect cable from equipment ground terminal to metal vehicle frame. Use #10 AWG or larger insulated copper wire.

YIf unit does not have GFCI re- ceptacles, use GFCI-pro- tected extension cord.

S-0854

OM-499 Page 35

Image 39
Contents OM-499 ProcessesDescription From Hobart to You Table of Contents Page Fumes and Gases can be hazardous Marks a special safety messageArc Welding Hazards Electric Shock can killEngine Hazards Compressed Air Hazards EMF Information Principal Safety StandardsLES Fumées ET LES GAZ peuvent être dangereux Signification des symbolesConsignes DE Sécurité Lire Avant Utilisation UN Choc Électrique peut tuerProvoquer des brûlures graves LE Soudage peut provoquer un in- cendie ou une explosionDES Particules Volantes peuvent blesser les yeux DES Pièces Chaudes peuvent’AIR Comprimé peut provoque r des blessures ’EXPLOSION DE LA Batterie peutDES Organes Mobiles peuvent provoquer des blessures LA Chaleur DU Moteur peut pro- voquer un incendieInformation sur les champs électromagnétiques Principales normes de sécuritéWelding Weld Output Rated Maximum Generator Power SpecificationsSymbol Definitions Weld, Power, And Engine SpecificationsBe damaged or unit could tip Dimensions, Weights, And Operating AnglesFuel Consumption Kohler-Powered Units Do not move or operate unit where itContinuous Welding Fuel Consumption Honda-Powered UnitsExceeding duty cycle can damage unit and void warranty Duty CycleHz Model Generator Power CurvesMAX MID MIN Volt-Ampere CurvesInstallation Installing Welding GeneratorGrounding Generator To Truck Or Trailer Frame Oil Grounding Generator When Supplying Building SystemsEngine Prestart Checks Kohler-Powered Units FuelEngine Prestart Checks Honda-Powered Units Connecting The Battery Electric-Start Models OnlyConnect negative cable last Stop engine before Connecting To Weld Output TerminalsSelecting Weld Cable Sizes 45 m 60 m 70 m 90 m 105 m 120 mControls Kohler-Powered Units Operating the Welding Generator50 Hz 60 Hz Controls Honda-Powered Units See Section Recoil-Start 2Electric-Start60 Hz 50 Hz Description Of Controls Honda-Powered Units See Section Generator Power Panel 495 218 USA Operating Auxiliary Equipment120 V x 10 a + 240 V x 9 a = 3.5 kVA/ KW OM-499 Australia Europe Asia Optional Generator Power PanelsGenerator Power Panel 495 Canada-CSA South Africa South AmericaIt exceeds 5500W Generator Power Panel RatingsMaintenance Label Maintenance100 h Routine Maintenance20 h 50 hIdle Speed Adjustment Overload Protection Honda-Powered UnitsAdjusting Engine Speed Kohler-Powered Units Weld/Power Speed AdjustmentStop engine. Close fuel valve Adjusting Engine Speed Honda-Powered UnitsThrottle Control Lever Adjustment Screw Pilot Screw Throttle Stop ScrewWelding TroubleshootingTroubleshooting Generator PowerCircuit board PC1 Check battery voltage electric-start models onlyViscosity oil for operating temperature EngineCircuit Diagram For Welding Generator 1 Electrical DiagramsCircuit Diagram For Welding Generator 2 Wiring Diagram For Welding Generator Wiring Diagram For Auxiliary Power Panels 1 Wiring Diagram For Auxiliary Power Panels 2 Selecting Equipment Generator Power GuidelinesVolts 115 Amps Resistive Load Grounding When Supplying Building SystemsHow Much Power Does Equipment Require? Earth ground if supplyingFarm/Home Equipment Rating Starting Watts Running Watts Approximate Power Requirements For Industrial MotorsApproximate Power Requirements For Farm/Home Equipment Industrial Motors Rating Starting Watts Running WattsContractor Rating Starting Watts Running Watts Approximate Power Requirements For Contractor EquipmentKVA/HP x HP x Power Required To Start MotorHow Much Power Can Generator Supply? Single-Phase Induction Motor Starting RequirementsWork like a Pro Typical Connections To Supply Standby PowerCurrent Load Watts Amperes Selecting Extension Cord Use Shortest Cord PossibleStick Welding Procedure Weld current starts when electrode touches work- pieceStick Welding Smaw Guidelines Electrode and Amperage Selection Chart Striking an Arc Scratch Start TechniqueStriking an Arc Tapping Technique 10-30 9090 End View of Work Angle Poor Weld Bead CharacteristicsGood Weld Bead Characteristics Positioning Electrode HolderElectrode Movement During Welding Conditions That Affect Weld Bead Shape16 in 1.6 mm Tack Welds Butt JointsLap Joint Tee JointPossible Causes Corrective Actions Troubleshooting PorosityTroubleshooting Excessive Spatter Weld TestTroubleshooting Incomplete Fusion Troubleshooting Lack Of PenetrationTroubleshooting Excessive Penetration Troubleshooting Burn-Through Troubleshooting Waviness Of BeadTroubleshooting Distortion Main Assembly Parts ListDia Part Dia Part Mkgs Description Quantity Generator Power Panels Item Dia Part Mkgs Description Quantity Support ServiceHobart Welding Products Contact your Distributor for