Repair

Outlet Valve

5. Clean as much excess material from outlet valve cavity as possible.

Removal

1.Engage trigger lock and put prime/pressure relief valve in UP position to relieve pressure.

ti19347a ti19350a

2. Remove material cup and battery.

ti19617a

ti19360a

3.Loosen set screws (34) from pressure control knob and remove knob.

34

ti19620a

4.Use thin screwdriver or allen wrench to turn outlet valve (31) clockwise and remove.

31

ti19614a

Installation

NOTE: Inlet valve must be fully installed before outlet valve can be installed.

1.Make sure prime/pressure relief valve is in UP posi- tion. Use a thin screwdriver or allen wrench and turn outlet valve (31) counter-clockwise to install.

31

ti19347a

ti19623a

2.Thread outlet valve in until it touches inlet ball. DO NOT TIGHTEN. Outlet valve should only be threaded until inlet ball does not move when touched.

ti19616a

3.Install pressure control knob. Turn knob fully counter-clockwise until it stops (“0” setting will line up with red dot). Torque set screws (34) to 40 in-lb (4.5 N•m).

34

ti19626a

ti19620a

ti19351a

3A2308C

29

Image 29
Contents Model Protective Coating Hand-Held Paint Sprayer 3A2308CTable of Contents Grounding Instructions Skin Injection Hazard Charger Electric SHOCK, Fire and Explosion Hazard Description Component IdentificationOperation Charging the BatteryCharger Status Indicator Lights Sprayer Status Indicator Trigger Unlocked red ring is visible Common ProceduresTrigger Locked Adjusting Pressure Ti19655a Ti19656a Ti19654a Ti19653a See Grounding Instructions, SetupStarting a New Job Perform Pressure Relief Procedure, Install/Service Filter if neededFilling and Installing Cup Install Tip/Guard Assembly if not installedPriming Pump Setting PressureTi19655a Ti19656a Ti19654a Ti19653a Triggering Sprayer Getting Started with Basic TechniquesAiming Sprayer Pulsating MaterialUnclogging Spray Tip/Guard Assembly Flushing Sprayer Shutdown and CleaningRemove cup and properly dispose contaminated fluid Storage Cleaning Sprayer ExteriorParts Part Description Qty Parts ListInstall/Service Filter, TroubleshootingRemoved. See Install/Service Filter Job or Refilling the Cup,See Charging the Battery, Spray Pattern Diagnostics See Shutdown and Cleaning, Inlet Valve RepairOutlet Valve Pressure Control Knob Pump Module/Drive Module Pump Rebuild Kit Clamshell Route wires from motor down the handle Motor/Control Board Replacement Kit Ti19632a Ti19641a Switch Assembly Install trigger lock over trigger with o-ring facing out Gear Replacement Ti19857a Ti19860a Metric Technical DataFCC Declaration for Battery Charger 3A2308C 3A2308C Graco Information Graco Standard Warranty