Graco 16H960, 16N655, 16N927, 16N654, 16N656 Remove cup and properly dispose contaminated fluid

Page 20

7.Disengage trigger lock, turn sprayer upside-down and trigger for approximately 15 seconds to recirculate material.

Operation

11.Remove cup and properly dispose contaminated fluid.

ti19374a

To avoid serious injury or damage to equipment, do not expose the sprayer electronics to flushing solvents. Keep sprayer at least 10 in. above the rim of the con- tainer when flushing.

ti19798a

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area. When flushing with solvents, always ground the sprayer and waste container.

8.Reverse tip to UNCLOG position. Put prime/pres- sure relief valve DOWN to spray position and trigger sprayer through tip into waste area for 1- 2 seconds.

ti19370a ti19346a ti14995a

ti19366a

9.Engage trigger lock. Put prime/pressure relief valve in UP position.

ti19350ati19347a

10.Unthread tip/guard from sprayer and soak in appro- priate flushing fluid.

ti19386a

ti19385a

12.Refill liner 1/2 full. Disengage trigger lock, turn sprayer upside-down and trigger sprayer for approximately 15 seconds to recirculate material.

ti19374a

ti19358a

13.Put prime/pressure relief valve DOWN to spray position. Spray the remaining amount of cleaning fluid through the front of the sprayer.

ti19346a

ti19404a

 

14.If sprayer is not completely clean, repeat steps 11 and 12.

15.Engage trigger lock and put prime/pressure relief valve UP to release pressure.

ti19350a

ti19347a

 

16.Remove material liner and lid and properly dispose. Properly dispose used fluid.

ti19385a

17.Clean Spray Tip/Guard assembly with clean flush- ing fluid. Use a soft brush to loosen and remove dried material if needed.

ti19344a

20

3A2308C

Image 20
Contents Protective Coating Hand-Held Paint Sprayer 3A2308C ModelTable of Contents Grounding Instructions Skin Injection Hazard Charger Electric SHOCK, Fire and Explosion Hazard Component Identification DescriptionOperation Charging the BatteryCharger Status Indicator Lights Sprayer Status Indicator Trigger Unlocked red ring is visible Common ProceduresTrigger Locked Adjusting Pressure Ti19655a Ti19656a Ti19654a Ti19653a See Grounding Instructions, SetupStarting a New Job Install/Service Filter if needed Perform Pressure Relief Procedure,Install Tip/Guard Assembly if not installed Filling and Installing CupSetting Pressure Priming PumpTi19655a Ti19656a Ti19654a Ti19653a Getting Started with Basic Techniques Triggering SprayerAiming Sprayer Pulsating MaterialUnclogging Spray Tip/Guard Assembly Shutdown and Cleaning Flushing SprayerRemove cup and properly dispose contaminated fluid Cleaning Sprayer Exterior StorageParts Parts List Part Description QtyTroubleshooting Install/Service Filter,Removed. See Install/Service Filter Job or Refilling the Cup,See Charging the Battery, Spray Pattern Diagnostics See Shutdown and Cleaning, Repair Inlet ValveOutlet Valve Pressure Control Knob Pump Module/Drive Module Pump Rebuild Kit Clamshell Route wires from motor down the handle Motor/Control Board Replacement Kit Ti19632a Ti19641a Switch Assembly Install trigger lock over trigger with o-ring facing out Gear Replacement Ti19857a Ti19860a Metric Technical DataFCC Declaration for Battery Charger 3A2308C 3A2308C Graco Standard Warranty Graco Information