Graco 16N654, 16H960, 16N655, 16N927, 16N656 important safety instructions Sprayer Status Indicator

Page 8

Operation

Sprayer Status Indicator

Red

Yellow

ti19361a

 

 

No light

Normal operation.

No action required.

 

 

 

 

 

 

 

 

Battery is too hot. Unit will

Change battery.

 

 

 

shut down until battery has

 

 

 

 

Allow battery to cool.

 

 

Solid Red

cooled.

 

 

 

 

 

 

 

 

 

 

 

Liquid has contacted control

Allow unit to dry.

 

 

 

board.

 

 

 

 

 

 

 

 

 

 

 

 

Motor is too hot and will shut

Increase tip size.

 

 

 

down if heavy use continues.

 

 

 

Flashing Red

Turn down pressure.

 

 

Unit will shut down until motor

 

 

 

Let unit cool down.

 

 

 

has cooled.

 

 

 

 

 

 

 

 

Battery is low or

Charge battery.

 

 

Solid Yellow

 

 

 

 

 

 

battery is too cold.

Warm up battery.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn pressure control

 

 

 

 

counter-clockwise to reduce

 

 

Flashing Yellow

High pressure signal. Gun will

pressure.

 

 

shut down after 1.5 seconds.

Increase tip size.

 

 

 

 

 

 

 

 

 

 

 

 

Material is too thin--do not thin

 

 

 

 

as much.

 

 

 

 

 

Solid red and solid yellow

Locked motor.

Bring sprayer in to service cen-

ter for diagnostics.

 

 

 

 

 

 

 

 

 

*NOTE: The sprayer status indicator light is visible for 10 seconds after the trigger is released.

8

3A2308C

Image 8
Contents Protective Coating Hand-Held Paint Sprayer 3A2308C ModelTable of Contents Grounding Instructions Skin Injection Hazard Charger Electric SHOCK, Fire and Explosion Hazard Component Identification DescriptionOperation Charging the BatteryCharger Status Indicator Lights Sprayer Status Indicator Trigger Unlocked red ring is visible Common ProceduresTrigger Locked Adjusting Pressure Ti19655a Ti19656a Ti19654a Ti19653a See Grounding Instructions, SetupStarting a New Job Install/Service Filter if needed Perform Pressure Relief Procedure,Install Tip/Guard Assembly if not installed Filling and Installing CupSetting Pressure Priming PumpTi19655a Ti19656a Ti19654a Ti19653a Getting Started with Basic Techniques Triggering SprayerAiming Sprayer Pulsating MaterialUnclogging Spray Tip/Guard Assembly Shutdown and Cleaning Flushing SprayerRemove cup and properly dispose contaminated fluid Cleaning Sprayer Exterior StorageParts Parts List Part Description QtyTroubleshooting Install/Service Filter,Removed. See Install/Service Filter Job or Refilling the Cup,See Charging the Battery, Spray Pattern Diagnostics See Shutdown and Cleaning, Repair Inlet ValveOutlet Valve Pressure Control Knob Pump Module/Drive Module Pump Rebuild Kit Clamshell Route wires from motor down the handle Motor/Control Board Replacement Kit Ti19632a Ti19641a Switch Assembly Install trigger lock over trigger with o-ring facing out Gear Replacement Ti19857a Ti19860a Metric Technical DataFCC Declaration for Battery Charger 3A2308C 3A2308C Graco Standard Warranty Graco Information