Campbell Hausfeld EZ5000, IN423200AV Cleaning & Storage, Rotate Spray Tip to Clean Position

Page 11
2
Figure 22 - Icon showing Clean Hose position

EZ5000 Series

Step 3 – Cleaning & Storage (Cont.)

changing buckets.

When you are sure that the pump is clean, get one more bucket of water. Place the suction tube in it and turn the One Touch

Control knob to the clean hose position (see Figure 22). Turn the reversible tip on the gun to the clean position.

Spray into a waste

bucket until clear water comes out of the gun. Submerge tip in water to avoid splashing. Another way to reduce splashing is to keep the tip angled above the fluid level.

For storage of six months or more, use a storage fluid such as Pump Protector. Follow directions provided by the manufacturer.

Coatings That Clean Up With Something Other Than Water

When the coating manufacturer rec- ommends mineral spirits or some other cleaning fluid, pour enough of the solution into a bucket to come about an inch above the suction filter. Do not use a waste bucket. Keep the bypass tube in the fluid bucket with the suc- tion tube. Allow the fluid to circulate for 10 minutes in the clean pump posi- tion (see Figure 21).

Turn the One Touch Control to the clean hose icon (see Figure 22). Turn the reversible tip on the gun to the clean position ( see Figure 23). Spray into a waste bucket until there is no

more fluid in the suction bucket. Submerge the tip in water to avoid splashing. Another way to reduce splashing is to keep the tip angled above the fluid level.

Dispose of solvent according to local ordinances.

For best results, repeat this process one more time with fresh cleaning fluid.

You can strain and reuse the cleaning fluid. Nothing else needs to be done for long term storage.

Figure 23 – Rotate Spray Tip to CLEAN Position.

www.chpower.com

11

Image 11
Contents Operating Instructions & Parts Manual EZ5000 Series SpecificationsGeneral Safety DescriptionImportant Safety Instructions Extension Cords Engage trigger lock by rotating lock as shown Trigger lockTools Required Set-UpPainting Fences When Painting OutsideWhen Painting Inside Painting Houses, Garages, EtcDoors PrimingMore on Walls Icon showing Highest Pressure position Using Your HousePainterRolling SprayingStorage Using YourCleaning Coatings That Clean Up With WaterRotate Spray Tip to Clean Position Cleaning & StorageMaintenance Chart Symptom Possible Causes Corrective Action Troubleshooting ChartSymptom Possible Causes To Free a Stuck Inlet For Replacement Parts, Call Limited Warranty Page Série EZ5000 SpécificationsSécurité générale Pieds 25-50 50100 100150 150250 250400 400-500 RallongesTableau 1 Rallonges pour l’appareil de 120 volts/15 a Suite Sécurité générale Préparation Sécurité générale InstallationEn peignant à l’intérieur En peignant à l’extérieurPeindre maisons, garages, etc Peindre les clôturesPortes Installation suiteÉtape 1 Amorçage Quelques autres mots sur les mursRégler la pression Étape 2 Utiliser votre HousePainterRouleau PulvériserRevêtements qui se nettoient à l’eau Étape 3 Nettoyage et rangementRevêtements se nettoyant avec autre chose que de l’eau Étape 3 Nettoyage et rangement suiteTableau d’entretien Mesure corrective Tableau de dépannageSymptôme Causes possibles Symptôme Causes possibles Mesure corrective Tableau de dépannage suiteTableau de dépannage suite Pour libérer une aspiration Coincée Pour les pièces de rechange, appeler le Garantie Limitée