Senco PC2053-1 owner manual Installation and BREAK-IN Procedures, Location of the Air Compressor

Page 8

INSTALLATION AND BREAK-IN PROCEDURES

Location of the Air Compressor

Your compressor comes to you completely assembled and ready for use. Operate the air compressor in a dry, clean, cool and well ventilated area. The air compressor pump and case are designed to allow for proper cooling. Clean or blow off dust or dirt that collects on the air compressor. A clean air compressor runs cooler and provides longer service. The ventilation openings on your air compressor are necessary to maintain proper operat- ing temperature. Do not place rags or other containers on or near these openings.

Voltage and Circuit Protection

See specification chart on page 5.

Extension Cords

Use extra air hose instead of an extension cord to avoid voltage drop and power loss to the motor.

If an extension cord must be used, be sure it is:

a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the compressor

in good condition

no longer than 50 feet

14 gauge (AWG) or larger. (Wire size increases as gauge number decreases.) 12 AWG, 10 AWG and 8 AWG may also be used. DO NOT USE 16 OR 18 AWG.

Grounding Instructions

RISK OF ELECTRICAL SHOCK! IN THE EVENT OF A SHORT CIRCUIT, GROUNDING REDUCES THE RISK OF SHOCK BY PROVIDING AN ES- CAPE WIRE FOR THE ELECTRIC CURRENT. THIS AIR COMPRESSOR MUST BE PROPERLY GROUNDED.

The air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances. The outlet must have the same configuration as the plug. See illustration. DO NOT USE AN ADAPT-

ER.

Inspect the plug and cord before each use. Do not use if there are signs of damage.

IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK.

Do not modify the plug that has been provided. If it does not fit the available outlet, the correct outlet should be installed by a qualified electrician.

If repairing or replacing cord or plug, the grounding wire must be kept separate from the current-carrying wires. Never connect the grounding wire to a flat blade plug terminal. The grounding wire has insulation with an outer surface that is green - with or without yellow stripes.

If these grounding instructions are not completely under- stood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.

Additional Regulators and

Controls

Since the air tank pressure is usually greater than that which is needed, a separate regulator is usually employed to control the air pressure ahead of any individual air driven device.

Separate air transformers which combine the function of air regulation, moisture and dirt removal should be used where applicable.

NOTE

It is not uncommon for the air tank to contain some water from the testing of the tank at the factory.

D23708

8-ENG

 

Image 8
Contents Accuset Table of Contents Important Safety Instructions Hazard What can Happen HOW to Prevent ITRisk of Explosion or Fire Risk of BurstingRisk of Electrical Shock Risk from Flying ObjectsRisk to Breathing Risk of Property Damage When Transporting Compressor Risk from Moving PartsRisk of Burns Risk of FallingSpecifications When you have finished using the air compressorGlossary Duty CycleDescription of Operation Installation and BREAK-IN Procedures Location of the Air CompressorVoltage and Circuit Protection Extension CordsOperating Procedures When you are finishedTroubleshooting Guide Problem Cause CorrectionProblem Cause Correction Parts Diagram Parts Available for this Unit Part Number DescriptionAIR Compressor Diagram Parts List Accuset Compressor and Parts Warranty Replacement of Compressor Due to Natural DisasterCompresor DE Aire Permantemente Lubricado Tabla DE Contenidos ¿QUÉ Puede OCURRIR? ¿CÓMO PREVENIRLO? PeligroRiesgo DE Explosión Riesgo DE Inhalación Riesgo DE Partes Móviles Riesgo DE QuemadurasRiesgo DE Caidas Riesgo DE Daños a LA Propiedad AL Transportar EL CompresorTabla DE Especificaciones GlosarioCiclo DE Trabajo AlmacenajeDescripción DE LA Operación Usaradaptadores Instrucciones Para Conectar a TierraControles y Reguladores Adicionales Procedimiento Para Operar Procedimiento para el AsentamientoNota Cuando usted termineSobreajustar Guía Para Detección DE ProblemasProblema Causa Solución La válvula Lista DE Repuestos Lista DE Partes Descripción Número DE ParteDiagrama DEL Compresor 15-SP D23708 Garantía DEL Compresor Accuset Y SUS Componentes Compresseur Dair À Lubrification Permanente Table DES Matières Mesures DE Sécurité Importantes Risque D’EXPLOSION OU D’INCENDIERisque D’ÉCLATEMENT Risque PréventionRisque DE Projection D’OBJETS Risque DE Choc ÉlectriqueRisque Relié AUX Pièces Mobiles Spécifications LexiqueCycle Opératoire EntreposageDescription DU Fonctionnement DE L’APPAREIL Directives DE Mise À LA Terre Régulateurs et contrôles supplémentairesPAS UN Calibre DE 16 OU DE 18 AWG ’ADAPTATEURUne fois que vous avez terminé Procédures D’UTILISATIONProcédures DE Mise EN Route Probleme Cause Correction Guide DE DépannagePour votre circuit de dérivation particulier Pièces Disponibles Pour CET Appareil Liste DES Pièces DescriptionD23708 14-FR 15-FR D23708 Garantie SUR LE Compresseur D’AIR ET LES Pièces Accuset Garantie DU Compresseur D’AIR