Senco PC2053-1 owner manual Problem Cause Correction

Page 11

TROUBLESHOOTING GUIDE

 

PROBLEM

CAUSE

 

CORRECTION

 

 

 

 

 

 

Air leak from safety valve.

Possible defect in safety valve.

Operate safety valve manually by pulling on ring. If

 

 

 

 

valve still leaks, it should be replaced.

 

 

 

 

 

 

 

Knocking Noise

Defective check valve.

Remove and clean, or replace.

 

 

 

 

 

 

 

Compressor is not supplying

Prolonged excessive use of air.

Decrease amount of air usage.

 

 

enough air to operate accesso-

Compressor is not large enough for air

Check the accessory air requirement. If it is higher than

 

 

ries.

 

 

 

requirement.

the SCFM or pressure supplied by your air compres-

 

 

 

 

sor, you need a larger compressor.

 

 

 

Hole in hose.

Check and replace if required.

 

 

 

Check valve restricted.

Remove and clean, or replace.

 

 

 

Air leaks.

Tighten fittings. (See Air Leaks Section of

 

 

 

 

Troubleshooting Guide.)

 

 

 

 

 

 

 

Motor will not run.

Tank pressure exceeds pressure switch

Motor will start automatically when tank pressure

 

 

 

“cut-in” pressure.

drops below “cut-in” pressure of pressure switch.

 

 

 

Wrong gauge wire or length of exten-

Check for proper gauge wire and cord length.

 

 

 

sion cord.

 

 

 

 

 

Check valve stuck open.

Remove and clean, or replace.

 

 

 

Loose electrical connections.

Check wiring connection inside pressure switch and

 

 

 

 

terminal box area.

 

 

 

Paint spray on internal motor parts.

Have checked at an Authorized Warranty Service

 

 

 

 

Center. Do not operate the compressor in the paint

 

 

 

 

spray area. See flammable vapor warning.

 

 

 

Possible defective motor.

Have checked at an Authorized Warranty Service

 

 

 

 

Center.

 

 

 

Fuse blown, circuit breaker tripped.

1. Check fuse box for blown fuse and replace, if

 

 

 

 

 

necessary. Reset circuit breaker. Do not use a

 

 

 

 

 

fuse or circuit breaker with higher rating than that

 

 

 

 

 

specified for your particular branch circuit.

 

 

 

 

2. Check for proper fuse. You should be using a

 

 

 

 

 

time delay fuse.

 

 

 

 

3.

Check for low voltage conditions and/or proper

 

 

 

 

 

extension cord.

 

 

 

 

4.

Disconnect the other electrical appliances from

 

 

 

 

 

circuit or operate the compressor in its own

 

 

 

 

 

branch circuit.

 

 

 

Pressure release valve on pressure

Bleed the line by pushing the lever on the pressure

 

 

 

switch has not unloaded head pres-

switch to the “off” position; if the valve does not open,

 

 

 

sure.

replace it.

 

 

 

 

 

 

 

Regulator knob continuous air

Dirty or damaged regulator internal

Replace regulator.

 

 

leak. Regulator will not shut off

parts.

 

 

 

 

at air outlet.

 

 

 

 

 

 

 

 

 

 

11-ENG

D23708

 

Image 11 Contents
Accuset Table of Contents Risk of Bursting Important Safety Instructions HazardWhat can Happen HOW to Prevent IT Risk of Explosion or FireRisk of Electrical Shock Risk from Flying ObjectsRisk to Breathing Risk of Falling Risk of Property Damage When Transporting CompressorRisk from Moving Parts Risk of BurnsDuty Cycle SpecificationsWhen you have finished using the air compressor GlossaryDescription of Operation Extension Cords Installation and BREAK-IN ProceduresLocation of the Air Compressor Voltage and Circuit ProtectionWhen you are finished Operating ProceduresProblem Cause Correction Troubleshooting GuideProblem Cause Correction Parts Diagram Part Number Description Parts Available for this UnitAIR Compressor Diagram Parts List Replacement of Compressor Due to Natural Disaster Accuset Compressor and Parts WarrantyCompresor DE Aire Permantemente Lubricado Tabla DE Contenidos ¿QUÉ Puede OCURRIR? ¿CÓMO PREVENIRLO? PeligroRiesgo DE Explosión Riesgo DE Inhalación Riesgo DE Daños a LA Propiedad AL Transportar EL Compresor Riesgo DE Partes MóvilesRiesgo DE Quemaduras Riesgo DE CaidasAlmacenaje Tabla DE EspecificacionesGlosario Ciclo DE TrabajoDescripción DE LA Operación Usaradaptadores Instrucciones Para Conectar a TierraControles y Reguladores Adicionales Cuando usted termine Procedimiento Para OperarProcedimiento para el Asentamiento NotaSobreajustar Guía Para Detección DE ProblemasProblema Causa Solución La válvula Lista DE Repuestos Descripción Número DE Parte Lista DE PartesDiagrama DEL Compresor 15-SP D23708 Garantía DEL Compresor Accuset Y SUS Componentes Compresseur Dair À Lubrification Permanente Table DES Matières Risque Prévention Mesures DE Sécurité ImportantesRisque D’EXPLOSION OU D’INCENDIE Risque D’ÉCLATEMENTRisque DE Choc Électrique Risque DE Projection D’OBJETSRisque Relié AUX Pièces Mobiles Entreposage SpécificationsLexique Cycle OpératoireDescription DU Fonctionnement DE L’APPAREIL ’ADAPTATEUR Directives DE Mise À LA TerreRégulateurs et contrôles supplémentaires PAS UN Calibre DE 16 OU DE 18 AWGUne fois que vous avez terminé Procédures D’UTILISATIONProcédures DE Mise EN Route Guide DE Dépannage Probleme Cause CorrectionPour votre circuit de dérivation particulier Pièces Disponibles Pour CET Appareil Description Liste DES PiècesD23708 14-FR 15-FR D23708 Garantie DU Compresseur D’AIR Garantie SUR LE Compresseur D’AIR ET LES Pièces Accuset