TOOL OPERATION CHECK:

Remove all fasteners from tool before performing tool operation check.

1.SEQUENTIAL TRIP OPERATION:

A.Press the contact trip against the work surface, without touching the trigger.

THE TOOL MUST NOT CYCLE.

B.Hold the tool off the work surface and pull the trigger.

THE TOOL MUST NOT CYCLE.

Release the trigger. The trigger must return to the trigger stop on the frame.

C.Pull the trigger and press the contact trip against the work surface.

THE TOOL MUST NOT CYCLE.

D.With finger off the trigger, press the contact trip against the work surface. Pull the trigger.

THE TOOL MUST CYCLE.

2.CONTACT TRIP OPERATION:

A.With finger off the trigger, press the contact trip against the work surface.

THE TOOL MUST NOT CYCLE.

B.Hold the tool off the work surface, and pull the trigger.

THE TOOL MUST NOT CYCLE.

C.With the tool off the work surface, pull the trigger. Press the contact trip against the work surface.

THE TOOL MUST CYCLE.

D.Without touching the trigger, press the contact trip against the work surface, then pull the trigger.

THE TOOL MUST CYCLE.

IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE THE FOLLOWING FOR SAFE OPERATION

Use the Bostitch pneumatic tool only for the purpose for which it was designed.

Never use this tool in a manner that could cause a fastener to be directed toward the user or others in the work area.

Do not use the tool as a hammer.

Always carry the tool by the handle. Never carry the tool by the air hose.

Do not alter or modify this tool from the original design or function without approval from Bostitch

Always be aware that misuse and improper handling of this tool can cause injury to yourself and others.

Never clamp or tape the trigger or contact trip in an actuated position.

Never leave a tool unattended with the air hose attached.

Do not operate this tool if it does not contain a legible WARNING LABEL.

Do not continue to use a tool that leaks air or does not function properly. Notify your

nearest STANLEY-BOSTITCH representative if your tool continues to experience functional problems.

9

Image 9
Contents LPF21PL / LPF33PT / LPF28WW Index IntroductionAIR Supply and Connections Safety InstructionsLoading Tool OperationOperating Modes Tool SpecificationsAIR Supply and Connections Loading the Tool LubricationFilter Cold Weather OperationTo Adjust the Fastener Depth Control Fastener Depth Control AdjustmentRemoving Nails Tool OperationOperation Sequential Trip OperationContact Trip Operation Tool Operation Check Assembly Procedure for Seals Replacement PartsAIR SUPPLY-PRESSURE and Volume Maintaining the Pneumatic ToolAvailable Accessories Problem Cause Correction Trouble ShootingIntroducción ÍndiceNota Suministro DE Aire Y Conexiones Instrucciones DE SeguridadAL Cargar LA Herramienta OperaciónMantenimiento DE LA Herramienta Especificaciones DE LA HerramientaModos DE Operación Suministro DE Airey Conexiones Carga DE LAS Herramientas LubricaciónFiltro Funcionamiento EN Clima FríoExtracción DE Clavos Ajuste DEL Control DE Profundidad DEL ClavoOperación DE LA Herramienta Para Ajustar EL Control DE Profundidad DEL ClavoAntes DE Manejar U Operar Esta Herramienta OperaciónOperación DEL Disparo Secuential Operación DEL Disparo DE ContactoRevisión Funcional DE LA Herramienta Operación DE LA Herramienta ContinuaciónFuncionamiento DEL Disparo Secuencial Funcionamiento DEL Disparo DE ContactoMantenimiento DE LA Herramienta Neumática Presión Y Volumen DEL Suministro DE AirePiezas DE Repuesto Procedimiento DE Ensamblaje Para LOS SellosAccesorios Disponibles El vástago de la válvula de disparo Tiene fuga de aire Solución DE ProblemasGarantie Limitée É.-U. et Canada seulement RemarqueAlimentation EN AIR Comprimé ET Raccordement Consignes DE SécuritéChargement DE L’APPAREIL FonctionnementModes DE Fonctionnement Caractéristiquestechniques DES OutilsAlimentation EN AIR ET Connexions Lubrification FiltreFonctionnement EN Basse Température Commande DE Réglage DE Profondeur DE Fixation Fonctionnement DE L’OUTILPour Régler LA Profondeur DE Fixation Fonctionnement Fonctionnement EN Mode Déclenchement SéquentielFonctionnement DE L’OUTIL Suite Fonctionnement PAR Déclenchement SUR ContactVérification DE L’ÉTAT DE Marche DE L’OUTIL Maintenance DE L’OUTIL PneumatiqueAccessoires Offerts Vérifiez l’équipement d’alimentation d’air Dépannage