Bostitch LPF21PL, LPF28WW, LPF33PT Lubrication, Loading the Tool, Filter, Cold Weather Operation

Page 6

LPF21PL-LPF33PT-LPF28WW_9R189680RC_BOS_MAN_JM_166762RevC_FSeries_Man.qxd 11/26/12 10:29 AM

OPERATING PRESSURE:

Do not exceed recommended maximum operating pressure as tool wear will be greatly increased.The air supply must be capable of maintaining the operating pressure at the tool. Pressure drops in the air supply can reduce the tool’s driving power. Refer to “TOOL SPECIFICATIONS” for setting the correct operating pressure for the tool.

FILTER:

Dirt and water in the air supply are major causes of wear in pneumatic tools. This tool is equipped with an internal filter. To maintain proper air flow the filter must be cleaned regularly. To clean the filter, remove the filter from the end cap and use compressed air from a blow gun to blow the dirt from the filter.

An in-line filter will help to get the best performance and minimum wear from the tool.The filter must have adequate flow capacity for the specific installation. The filter has to be kept clean to be effective in providing clean compressed air to the tool. Consult the manufacturer’s instructions on proper maintenance of your filter. A dirty and clogged filter will cause a pressure drop which will reduce the tool’s performance.

LUBRICATION

Frequent, but not excessive, lubrication is required for best performance. Use Bostitch Air Tool Lubricant, PREMOIL- 4oz, or equivalent. Do not use detergent oil or additives as these lubricants will cause accelerated wear to the seals and bumpers in the tool, resulting in poor tool performance and frequent tool maintenance. Only a few drops of oil at a time is necessary. Too much oil will only collect inside the tool and will be noticeable in the exhaust cycle.

COLD WEATHER OPERATION:

For cold weather operation, near and below freezing, the moisture in the air line may freeze and prevent tool operation. We recommend the use of Bostitch winter formula air tool lubricant, WINTEROIL-4oz, or permanent antifreeze (ethylene glycol) as a cold weather lubricant.

CAUTION: Do not store tools in a cold weather environment to prevent frost or ice formation on the tools operating valves and mechanisms that could cause tool failure.

NOTE:Some commercial air line drying liquids are harmful to “O”-rings and seals – do not use these low temperature air dryers without checking compatibility.

LOADING THE TOOL

EYE PROTECTION which conforms to ANSI specifications and provides protection against flying particles both from the FRONT and SIDE should ALWAYS be worn by the operator and others in the work area when connecting to air supply, loading, operating or servicing this tool. Eye protection is required to guard against flying fasteners and debris, which could cause severe eye injury.

The employer and/or user must ensure that proper eye protection is worn. Eye protection equipment must conform to the requirements of the American National Standards Institute, ANSI Z87.1 and provide both frontal and side protection. NOTE: Non-side shielded spectacles and face shields alone do not provide adequate protection.

TO PREVENT ACCIDENTAL INJURIES:

Never place a hand or any other part of the body in nail discharge area of tool while the air supply is connected.

Never point the tool at anyone else.

Never engage in horseplay.

Never pull the trigger unless nose is directed at the work.

Always handle the tool with care.

Do not pull the trigger or depress the trip mechanism while loading the tool.

1. Load Nails. Hold nailer with

2. Pull pusher back.

3. Allow pusher to slide forward

magazine tilted downward.

 

until it contacts the last nail.

Insert stick of nails,

 

 

NOTE: Use only nails recommended for use in Bostitch Framing nailers or nails which meet the Bostitch specifications.

6

Image 6
Contents LPF21PL / LPF33PT / LPF28WW Introduction IndexLoading Tool Safety InstructionsAIR Supply and Connections OperationTool Specifications Operating ModesAIR Supply and Connections Filter LubricationLoading the Tool Cold Weather OperationRemoving Nails Fastener Depth Control AdjustmentTo Adjust the Fastener Depth Control Tool OperationOperation Sequential Trip OperationContact Trip Operation Tool Operation Check AIR SUPPLY-PRESSURE and Volume Replacement PartsAssembly Procedure for Seals Maintaining the Pneumatic ToolAvailable Accessories Trouble Shooting Problem Cause CorrectionIntroducción ÍndiceNota AL Cargar LA Herramienta Instrucciones DE SeguridadSuministro DE Aire Y Conexiones OperaciónMantenimiento DE LA Herramienta Especificaciones DE LA HerramientaModos DE Operación Suministro DE Airey Conexiones Filtro LubricaciónCarga DE LAS Herramientas Funcionamiento EN Clima FríoOperación DE LA Herramienta Ajuste DEL Control DE Profundidad DEL ClavoExtracción DE Clavos Para Ajustar EL Control DE Profundidad DEL ClavoOperación DEL Disparo Secuential OperaciónAntes DE Manejar U Operar Esta Herramienta Operación DEL Disparo DE ContactoFuncionamiento DEL Disparo Secuencial Operación DE LA Herramienta ContinuaciónRevisión Funcional DE LA Herramienta Funcionamiento DEL Disparo DE ContactoPiezas DE Repuesto Presión Y Volumen DEL Suministro DE AireMantenimiento DE LA Herramienta Neumática Procedimiento DE Ensamblaje Para LOS SellosAccesorios Disponibles Solución DE Problemas El vástago de la válvula de disparo Tiene fuga de aireRemarque Garantie Limitée É.-U. et Canada seulementChargement DE L’APPAREIL Consignes DE SécuritéAlimentation EN AIR Comprimé ET Raccordement FonctionnementCaractéristiquestechniques DES Outils Modes DE FonctionnementAlimentation EN AIR ET Connexions Lubrification FiltreFonctionnement EN Basse Température Commande DE Réglage DE Profondeur DE Fixation Fonctionnement DE L’OUTILPour Régler LA Profondeur DE Fixation Fonctionnement DE L’OUTIL Suite Fonctionnement EN Mode Déclenchement SéquentielFonctionnement Fonctionnement PAR Déclenchement SUR ContactMaintenance DE L’OUTIL Pneumatique Vérification DE L’ÉTAT DE Marche DE L’OUTILAccessoires Offerts Dépannage Vérifiez l’équipement d’alimentation d’air