Calibrating Depth | |
Scale |
|
The depth scale on the infeed table can be cali- | |
brated or "zeroed" if it is not correct. |
|
Tools Needed | Qty |
Straightedge | 1 |
Phillips Screwdriver | 1 |
To calibrate the depth scale: |
|
1.DISCONNECT JOINTER FROM POWER SOURCE!
2.Loosen the infeed table positive stop bolts.
3.Use the straightedge to help adjust the infeed table exactly even with the outfeed table, as shown in Figure 59.
������������ ������� ������
Figure 59. Infeed table even with outfeed table.
4.Using a screwdriver, adjust the scale pointer to zero (Figure 60), then reset the infeed table positive stops.
Setting Fence Stops
The fence stops simplify the task of adjusting the fence to 45˚ inward, 90˚, and 45˚ outward (135˚).
Tools Needed | Qty |
45° Square | 1 |
90° Square | 1 |
Sliding Bevel | 1 |
Wrench 10mm | 1 |
Hex Wrench 4mm | 1 |
To set the 45˚ inward fence stop: |
|
1.Tilt the fence approximately 45° inward (Figure 61) onto the positive stop bolt.