5-3. Troubleshooting
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Problem |
| Solution | |
|
|
| ||
Unit is completely inoperative. |
| Check continuity of Power switch S1, and replace if necessary. | ||
|
|
|
|
|
|
|
|
| Reset circuit breaker CB1 if open. |
|
|
|
|
|
|
|
|
| Check input power source. See welding power source Technical Manual. |
|
|
| ||
Wire does not feed, unit completely inop- |
| Turn Power switch On. | ||
erative. |
|
| ||
| Check 14−pin receptacle connections. | |||
|
|
|
| |
|
|
|
|
|
|
|
|
| Check input power or the CB |
|
|
| ||
Wire does not feed. |
| Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s | ||
|
|
|
| Manual. |
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check drive motor and control board PC1. |
|
|
| ||
Wire feeds erratically. |
| Readjust hub tension and drive roll pressure. | ||
|
|
|
|
|
|
|
|
| Use correct size drive roll (see Parts List). |
|
|
|
|
|
|
|
|
| Clean or replace dirty or worn drive roll. |
|
|
|
|
|
|
|
|
| Remove weld spatter around nozzle opening. |
|
|
|
|
|
|
|
|
| Replace contact tip or liner. See gun Owner’s Manual. |
|
|
|
|
|
|
|
|
| Check wiring between Motor Board and Encoder |
|
|
| ||
Electrode wire feeding stops or feeds |
| Realign drive rolls. | ||
erratically during welding. |
|
| ||
| Check hub assembly (see Parts List). | |||
|
|
|
| |
|
|
| ||
Wire feeds as soon as power is applied. |
| Check gun trigger. See gun Owner’s Manual. | ||
|
|
| ||
Gas valve rattles loudly and wire feeds |
| Check for short between gun trigger leads and weld cable. Repair or replace gun trigger leads. | ||
slowly or erratically. |
|
| ||
|
|
| ||
Gas does not flow; wire feeds. |
| Check gas valve and flowmeter. | ||
|
|
| ||
Wire feeds, but gas does not flow with |
| Check coil voltage and connections of gas valve. Check continuity of coil. Replace if necessary. | ||
gun trigger pressed. |
|
| ||
| Check continuity of Purge switch, and replace if necessary. | |||
|
|
|
| |
|
|
| ||
Software or visualization problems. |
| Recall factory parameters as explained in this manual. | ||
|
|
|
|
|
|
|
|
| Call a Factory Authorized Service Agent. |
|
| |||
Wire feeds and electrode wire is ener- | Check coil voltage and connections of gas valve GS1. Check continuity of coil. Replace if necessary. | |||
gized, but gas flow is irregular. |
|
| ||
| Clear blockage in gas hose or replace hose. | |||
|
|
|
| |
|
|
|
|
|
|
|
|
| Clear blockage in gun. See gun Owner’s Manual. |
|
|
| ||
Motor runs at full speed. |
| Check motor control board and connections, and replace if necessary. | ||
|
|
|
|
|
|
|
|
| Check wiring between Motor Board and Encoder |
|
| |||
Wire drive motor coasts (no brake at trig- | Check motor control board PC1 and connections, and replace if necessary. | |||
ger release). |
|
| ||
|
|
| ||
Meter does not work properly. |
| Recall factory parameters as explained in this manual. | ||
|
|
|
|
|